Deep AC cleaning

AC cleaning in Petromin

In Petromin, south Jeddah, AC cleaning is essential in the large administrative and warehouse buildings that run at high intensity. Alrabih's team cleans the indoor units with a protective bag and removes dust from the evaporator coil, blower wheel and drain pan.

  • Protective bag
  • Clean coil
  • Clear drain

Clients We're Proud to Serve

Organisations and companies that trusted Alrabih with their projects.

  • Saudi Aramco
  • Ministry of Energy
  • Royal Saudi Land Forces
  • Royal Saudi Naval Forces
  • Al Baik
  • Centro Hotels by Rotana
  • King Abdullah Economic City
  • First Mills
  • Juffali
  • eXtra
  • Dr. Soliman Fakeeh Medical Center
  • Alesayi Motors
  • Abu Zaid
  • Water Desalination
  • Attieh Steel
  • SSCO
  • Creet
  • Emad Rizq
  • Alfaneyah
  • Rawat Alam Al Tasmeem
  • IBI Magix Arabia — Construction Services
  • Midtown for Construction
  • Petra Engineering Industries Co.
  • Hyrmas
  • Batterjee Medical College
  • Advanced Horizons Contracting Company
  • D.Metals
  • Benchbox — Masters of Space
  • Sadafco
  • Umm Al-Qura University
  • Saudi Arabian Drug Store (SADS)
  • Foamco
  • Ahmad A. R. Bin Afif Industries Co. (Sandwich Panel Factory)
  • Namariq
  • ALS

When your AC needs a deep clean

  1. 1

    Musty smell when you switch on

    Jeddah's high humidity creates ideal conditions for mould on the drain pan and evaporator fins. If you notice a sharp smell the moment the unit starts, the most common cause is mould built up inside the indoor unit.

  2. 2

    Weak cooling from a working unit

    A thin layer of dust on the evaporator fins reduces heat transfer noticeably. A dirty blower wheel cuts airflow without any fault in the compressor or refrigerant. Cleaning restores the unit's performance to what it was.

  3. 3

    A unit that has not been cleaned in a long time

    Jeddah's heavy dust and salt-laden sea air build up on the outdoor coil and block airflow paths. The unit runs but the compressor works harder than it should; cleaning both coils together reduces that load.

Who it's for

  • Mould smell bothering your family

    We clean the evaporator, blower wheel and drain pan in your home unit with a protective bag keeping your furniture and walls dry.

    Ask on WhatsApp
  • Your office AC cooling has weakened

    We strip the indoor unit, wash every component and check the outdoor coil so the unit performs as it did, with minimal disruption to your working day.

    Ask on WhatsApp

What the cleaning covers

  • Protective bag fitted first
  • Air filter and evaporator fins
  • Blower wheel and drain pan
  • Drain line cleared and checked
  • Outdoor coil and condenser fins
Request a quote

How we work

How we work

  1. 1

    Tell us the unit type

    WhatsApp us the unit type, how many units and your district, and we will book a time that suits you, Saturday to Thursday.

  2. 2

    Protect the room and open the unit

    We fit the protective bag under the indoor unit to collect wash water, then remove the cover, filter and blower wheel to reach the evaporator and drain pan.

  3. 3

    Pressure wash and sanitise

    We wash the evaporator, blower wheel and drain pan at the right pressure with a sanitising agent, then check the drain flows cleanly before reassembly.

  4. 4

    Outdoor coil and start-up

    We move to the outdoor unit, clear dust and salt deposits from the coil and condenser fins, then run the AC and confirm airflow and cooling before we leave.

A thorough clean or a quick wipe?

AlrabihThe usual way
Protective bagFitted before washingUsually skipped
Blower wheelRemoved and washedWiped on the outside
Drain lineChecked and clearedLeft untouched
Outdoor coilCleaned as part of the jobLeft for another visit
Drain panWashed and sanitisedDry-wiped only

Some of our work

Ductwork, rooftop units and diffusers, from work we've completed in Jeddah.

  • Galvanized rectangular duct trunk with branch takeoffs and round diffusers, hung from a black ceiling, a Carrier unit visible behind — interior finishing stage.
  • Round diffusers and a spiral duct trunk in a tiled stairwell service shaft.
  • Rooftop ductwork and an exhaust fan, with Jeddah buildings in the background.
  • Rooftop packaged AC units with rectangular duct transitions, city buildings behind.
  • Insulated rooftop duct run beside a packaged unit, a warehouse roof in the background.
  • A grid of round diffusers in an open-plan office ceiling, mid-construction.
  • An insulated rooftop duct elbow, against a mountainous backdrop.
  • Large insulated ductwork running along a factory ceiling, with workers visible below.
  • A yellow round diffuser mid-installation, with spiral duct and a suspended ceiling grid.
  • Duct insulation wrap in progress on a construction site, bare duct still exposed.
  • A black-painted duct trunk with round diffusers and track lighting, in a finished retail interior.
  • An indoor AHU unit connected to round ductwork in a mechanical plant room, exposed concrete ceiling.
Similar project? Send us the details

Customer reviews

What our customers say

4.8

From 10 Google reviews

  • Muhammadramzan 2641

    “MashaaAllah. Services are so good. Behaviour and kindness 100/100. Prices are less then Market. Fully recommended”

  • shahzeb armani

    “Wow. Prices are so comfortable. Outstanding services. People are so talented and nice”

  • Tawfik AlyawerLocal Guide

    “U can find all u need for air conditioning”

Read every review on Google

Your satisfaction matters to us! If you had a great experience with us, we'd love a 5-star rating and a kind review.

Worked with us? Leave a review

Service areas

We come to you anywhere in Jeddah

From Al Shiraa and Al Yaqout in the north to Al Thaghr and Al Quraiyat in the south, with our base in Al Aziziyah.

Map of Jeddah by sector, with Alrabih's base in Al Aziziyah
Don't see your district?Message us. We most likely cover it.

What sets this district apart

Petromin is a sprawling industrial and administrative zone with modern, purpose-built structures housing corporate offices, meeting halls and storage warehouses. AC units here run continuously during working hours to cool large open spaces, so dust builds up faster than in residential areas. Regular cleaning keeps cooling efficiency high and prevents stale odours in these large enclosed spaces.

Petromin lies in Jeddah's industrial south sector, an area of modern administrative and storage buildings with large open-plan designs.

Most Petromin buildings have central or multiple split units to cover the large open spaces and halls.

The AC setup in Petromin

  1. 1

    Central AC units on rooftops

    Most Petromin administrative and warehouse buildings have central units on rooftops with extensive internal distribution ducting.

  2. 2

    Multiple split units in offices and halls

    Some of Petromin's large offices and meeting halls have several split units distributed to ensure even cooling.

  3. 3

    Outdoor units on tall walls and roofs

    Outdoor units sit on tall walls or modern building roofs, requiring safe work at height.

Before the visit

Before our visit in Petromin

  1. 1

    Confirm team access to rooftops

    If units are on rooftops, ensure the team can reach them safely before the scheduled visit.

  2. 2

    Coordinate with building or company management

    Inform management of the visit time to avoid clashing with critical administrative or storage operations.

  3. 3

    Arrange safe parking for equipment and vehicle

    Wide paved grounds allow safe parking close to the building; confirm the preferred location before the visit.

FAQ

Questions about AC cleaning

Will the wash water stain my furniture or ceiling?

We fix a sealed protective bag under the indoor unit before any pressure washing begins. The bag collects all the wash water and channels it away from your wall and furniture. This step is not optional in how we work.

Will the mould smell disappear completely after cleaning?

In most cases the smell goes once the evaporator, blower wheel and drain pan are washed with a sanitising agent. If the smell comes from very old build-up or a drain line problem, we diagnose the cause on site and tell you exactly what is needed.

How does Jeddah's dust and salty air affect the outdoor coil?

Heavy dust and salt carried by sea air collect between the condenser fins and block airflow. This raises condensing pressure and makes the compressor work harder than it was designed to. Cleaning the outdoor coil regularly keeps the compressor performing as it should and extends its life.

Can you clean a window unit the same way?

Yes, a window unit needs similar work: filter, evaporator, blower wheel and drain pan, plus the outdoor coil built into the same casing. The difference is in how it is opened and accessed, which the technician works out after seeing where the unit is installed.

Can cleaning fix water dripping from the indoor unit?

Dripping usually comes from a blocked drain pan or a drain line that does not slope correctly. Cleaning the pan and checking that the line has the right fall resolves the problem in many cases. If the cause is different, the technician diagnoses it on site and explains exactly what is needed.

Do you clean AC units in Petromin's large warehouses?

Yes, we service all Petromin warehouses and buildings. We clean both indoor and outdoor units and coordinate with building management to avoid disrupting work hours.

Petromin buildings are large with paved grounds, how do you handle the distances?

Our team reaches the wide paved grounds easily with no issues accessing parking or reaching outdoor units on roofs or walls.

Industrial dust around Petromin increases AC fouling, is that noticeable?

Yes, industrial dust builds up faster on the evaporator coil and blower wheel, so cleaning every three months or sooner is needed in this zone.

Large Petromin buildings have heavy-duty power, does that affect cleaning?

Adequate power supply simplifies our work, but we disconnect the unit before cleaning and reconnect it carefully after confirming safety.

The Jeddah corniche in cool weather

Restore your AC's freshness and airflow

WhatsApp us the unit type, number of ACs and your district, and we will arrange the cleaning visit, Saturday to Thursday, eight in the morning to eight at night.

CallWhatsApp