In Al Rawdah, west Jeddah, fitting air outlets and grilles in modern villas with spacious rooms and varying ceiling heights requires precision work. Alrabih's team chooses the diffuser size, plenum box and flexible duct link based on a site survey, not guesswork.
4.9 on Google- Galvanized plenums
- Flexible duct links
- Saudi-made grilles
Clients We're Proud to Serve
Organisations and companies that trusted Alrabih with their projects.
Is it for you?
When your project needs this work
- 1
A duct network awaiting its outlets
The main duct runs are in place, but the plenum boxes and grilles are not yet fitted. This stage needs its own care: correct sizing for each plenum box and a match between the flexible duct diameter and the grille neck.
- 2
Grilles making noise or staining the ceiling
A constant air hiss or black marks around a grille point to a problem with the plenum box, the flexible duct link or the outlet angle. In Jeddah's humidity, an unbalanced cold outlet stains the ceiling faster than in a dry climate.
- 3
A new build or an extension
In new builds and extensions the number and type of air outlets are set at design stage, then the plenum boxes are fabricated from G90 galvanized sheet from SABIC and installed to the approved duct layout.
Who it's for
Living in a villa with ductwork in place but no outlets yet
We survey each branch point, fabricate the plenum boxes and fit the right grilles for each room.
Ask on WhatsAppManaging a commercial building with noisy grilles
We inspect the flexible duct links and plenum boxes and correct the cause of the noise and ceiling staining.
Ask on WhatsApp
What the job covers
What the work covers
- Fabricating insulated plenum boxes
- Supplying and fitting flexible ducts
- Supplying Saudi-made air grilles
- Fitting dampers inside plenums
- Setting grilles and airflow
How we work
How we work
- 1
Site survey and outlet sizing
The technician visits the site, measures each branch point in the duct network, and decides the grille type and flexible duct diameter suited to the room size and ceiling height.
- 2
Plenum box fabrication
Plenum boxes are made in our workshop from G90 galvanized sheet from SABIC to the dimensions the survey set, with internal glass-wool insulation fitted before they leave for site.
- 3
Installation and network connection
Each plenum box is fixed to the main duct branch, and the flexible duct of the correct diameter is connected between it and the ceiling grille opening, with the air damper fitted where the layout requires.
- 4
Balance check and handover
After the system is running, the technician sets the grille vanes and air dampers and checks that cooling is distributed evenly across the space before handover, with a one-year warranty.
Why Alrabih?
A calculated fit or a quick connection?
| Alrabih | The usual way | |
|---|---|---|
| Plenum box | Made to size with internal insulation | Standard size, may not fit |
| Flexible duct | Diameter matched to each outlet | One diameter throughout |
| Grille | Type and size for the room | Whatever is in stock |
| Air damper | Fitted where the layout requires | Omitted or closed off |
| Internal insulation | Fitted in workshop before install | Added on site or omitted |
Everything your AC needs, from one team
From system design and duct fabrication to installation, commissioning and maintenance.

Split AC installation
Request this service
Duct installation
Request this service
Central AC installation
Request this service
Duct fabrication
Request this service
Cold room installation
Request this service
Electro-mechanical works
Request this service
Chiller & AHU installation
Request this service
HVAC design
Request this service
Copper piping works
Request this service
Air outlets and grilles installation
Request this service
Ventilation and exhaust systems
Request this service
HVAC controls and automation
Request this service
Duct insulation
Request this service
AC repair & faults
Request this service
AC cleaning
Request this service
Refrigerant charging
Request this service
Central AC maintenance
Request this service
Chiller maintenance
Request this service
AC removal & refitting
Request this service
Duct cleaning & sanitising
Request this service
AC servicing by brand
Request this service
Operation & maintenance contracts
Request this service
AHU maintenance
Request this service
Testing and commissioning
Request this service
Fridge & freezer service
Request this service
Cold rooms
Request this service
Display fridges & chillers
Request this service
Factory HVAC
Request this service
Warehouse HVAC
Request this service
Villa & home HVAC
Request this service
Hotel HVAC
Request this service
School HVAC
Request this service
Hospital HVAC
Request this service
Mosque HVAC
Request this service
Mall & retail HVAC
Request this service
Restaurant & cafe HVAC
Request this service
Government building HVAC
Request this service
Sports club HVAC
Request this service
Tower and office building HVAC
Request this service
University HVAC
Request this service
G90 galvanized steel and aluminium sheets
Request this service
Mueller and Lawton copper pipes
Request this service
Air grilles and diffusers (Saudi-made)
Request this service
Central AC accessories and materials
Request this service
Some of our work
Ductwork, rooftop units and diffusers, from work we've completed.
Customer reviews
What our customers say
- Waleed Daadouch
“The nicest treatment from the showroom team, and their prices are very competitive.”
Translated from Arabic
- Muhammadramzan 2641
“MashaaAllah. Services are so good. Behaviour and kindness 100/100. Prices are less then Market. Fully recommended”
- RHAM rhamLocal Guide
“May God grant them success. Refined and respectful treatment.”
Translated from Arabic
- shahzeb armani
“Wow. Prices are so comfortable. Outstanding services. People are so talented and nice”
- Shakeel Ahmed
“Nice experience very cooperative. Nice conducting with all customers”
- Tawfik AlyawerLocal Guide
“U can find all u need for air conditioning”
Your satisfaction matters to us! If you had a great experience with us, we'd love a 5-star rating and a kind review.
Worked with us? Leave a reviewService areas
We come to you anywhere in Jeddah
From Al Shiraa and Al Yaqout in the north to Al Thaghr and Al Quraiyat in the south, with our base in Al Aziziyah.

What sets this district apart
Al Rawdah is a modern residential district dominated by multi-storey villas with open-plan spaces, meaning duct networks run longer distances and need different pipe diameters depending on the load to each room. Central AC is the standard choice here, and the outdoor unit sits far from the indoor spaces, so the quality of the installation and the thermal insulation of the plenum box become essential to prevent energy loss and noise.
Al Rawdah lies in west Jeddah, a district of modern, spaced villas with varied ceiling types and room layouts.
Most modern villas in Al Rawdah rely on a single central AC system with ductwork covering multiple rooms, requiring air outlets of different sizes per space.
The AC setup in Al Rawdah
- 1
Single central plenum box in the ceiling space
Modern villas typically have adequate ceiling space to house one insulated plenum box that distributes air to multiple rooms.
- 2
Flexible duct links from plenum to each room
Flexible duct links run from the central plenum to air outlets in each room, with insulation that reduces thermal loss.
- 3
Multiple diffusers scaled to room sizes
Each room gets a diffuser sized to fit its area and ceiling height, ensuring even air distribution.
Before the visit
Before our visit in Al Rawdah
- 1
Tell us the room layout and ceiling details
Send us a floor plan showing ceiling heights and room locations so the team can plan the duct routes precisely.
- 2
Confirm access to the ceiling void
Check that the ceiling void is safe and accessible for installation and inspection, and tell us about any obstructions like wiring or pipes.
- 3
Specify diffuser locations on ceilings
Decide with the designer where the air outlets will sit on each ceiling before the installation day to avoid changes later.
More districts for Air outlets and grilles installation
Other services in Al Rawdah
FAQ
Questions about Air outlets and grilles installation
What is the difference between a grille and a diffuser, and which suits my room?
A grille directs air in set directions through adjustable vanes and is common in ceilings and walls. A diffuser spreads air in a wide circle along the ceiling and suits open rooms and commercial spaces. The choice between the two depends on room dimensions, ceiling height and plenum position, all of which the technician decides at the site survey.
Why do black marks appear around a grille after a short time?
The usual cause is warm air leaking through a gap in the flexible duct connection or around the plenum box, which meets the cold surface near the grille and deposits dust. Jeddah's high humidity speeds the process up. The fix is sealing the connection and insulating the plenum box properly, not just cleaning the ceiling.
Do you make the plenum boxes yourselves or buy them ready-made?
We make them in our own workshop from G90 galvanized sheet from SABIC to the dimensions the site survey sets for each branch point. Internal glass-wool insulation is fitted in the workshop before each box goes to site. This lets us match the size precisely rather than adapting a standard box that may not suit the opening.
Can extra air outlets be added to an existing duct network?
Yes, within what the existing network capacity and main duct space allow. The technician checks the duct diameter at the proposed branch point and confirms that pressure is sufficient to feed the new outlet without weakening the existing ones. Competitive prices apply, with discounts by quantity and project size.
Does the flexible duct link affect the noise level inside the room?
Yes. A flexible duct link narrower than required speeds the air up and produces an audible whistle. One that is too long or bent at a sharp angle creates turbulent airflow. The technician decides the correct diameter and duct path at the site survey, based on the distance between the plenum box and the grille opening and the room size.
Modern villas in Al Rawdah have high ceilings, does that affect the diffuser choice?
Yes, higher ceilings need a diffuser with a different air-distribution pattern to reach all corners without cold draughts. We decide on the type after surveying the site.
The distance from the outdoor unit to the rooms is long, does that affect the ductwork?
Longer duct runs increase heat loss, so we use flexible duct links with good thermal insulation and a fully insulated plenum box to retain the temperature.
Coastal humidity may affect the plenum box, how do you protect it?
The plenum box is made from G90 galvanized sheet with internal glass-wool insulation to guard against humidity and condensation. Proper installation prevents water pooling inside.
How do you choose the flexible duct size for the run?
The flexible duct size depends on the main duct diameter and the volume of air needed at each diffuser. The site survey determines all this before installation begins.