Precision-made ductwork
AC duct manufacturing in Al Baghdadiyah Al Sharqiyah
In Al Baghdadiyah Al Sharqiyah in central Jeddah, residential blocks, hotels and hospitals need reliable central AC. Alrabih manufactures ductwork to exact dimensions in the workshop, fully insulated and ready to hang.
- Sealed seams
- Full insulation
- Delivered ready
Clients We're Proud to Serve
Organisations and companies that trusted Alrabih with their projects.
When duct quality makes the difference
- 1
Duct losing cold air
An open seam or an unsealed joint loses cold air before it reaches the room. We close every seam with Foster sealant in the workshop before shipping, so the seal does not depend on site work alone.
- 2
Condensation wetting the ceiling
In Jeddah's humid air any bare metal surface sweats and drips onto the ceiling or damages the unit insulation. We wrap with Kimmco or Armaflex at the thickness the site calls for.
- 3
A project with many duct runs
A villa or commercial building needs main trunks, branches and plenums in several sizes. We make sections in the workshop numbered to the site plan, so the hanging crew assembles without cutting or adjusting.
Who it's for
Replacing your villa's AC and need new ductwork
We make supply and return trunks and plenums to your villa's dimensions, insulated and numbered, ready for the hanging crew without any on-site cutting.
Ask on WhatsAppRunning a commercial fit-out that needs duct runs
We take your project drawings and produce numbered sections in batches matched to your site schedule, so the hanging crew is never waiting on supply.
Ask on WhatsApp
What the manufacturing covers
- Supply and return trunks
- Unit plenums to opening size
- Seams sealed with Foster
- Kimmco or Armaflex outer wrap
- Numbered sections ready to hang
How we work
How we work
- 1
Send sizes or drawings
Send us the duct drawing or a list of section sizes. If sizes are not fixed yet, we agree a site survey before production starts.
- 2
Review sizes and sheet gauge
We check each section's dimensions and pick the right sheet thickness for the duct size, then confirm quantities with you before cutting begins.
- 3
Fabricate, seal and insulate
We cut and fold the G90 galvanised sheet, lock the seams with Foster sealant, and wrap each section with Kimmco or Armaflex insulation in the workshop before shipment.
- 4
Number and deliver
We mark each section with its position and dimension from the site plan, so the hanging team identifies every piece without confusion and starts work on arrival.
Workshop-made or site-cut duct?
| Alrabih | The usual way | |
|---|---|---|
| Sealing | Foster on every seam in workshop | Uneven site sealing |
| Insulation | Kimmco or Armaflex fully wrapped | Partial or delayed wrap |
| Sheet gauge | Chosen for each duct size | One gauge for everything |
| Assembly time | Numbered, assembled straight away | Cut and adjust on site |
| Joint fit | Workshop dimensions close every joint | Hand trimming breaks the seal |
Everything your AC needs, from one team
From system design and duct fabrication to installation, commissioning and maintenance.

Split AC installation
Request this service
Duct installation
Request this service
Central AC installation
Request this service
Duct fabrication
Request this service
Cold room installation
Request this service
Electro-mechanical works
Request this service
Chiller & AHU installation
Request this service
HVAC design
Request this service
AC repair & faults
Request this service
AC cleaning
Request this service
Refrigerant charging
Request this service
Central AC maintenance
Request this service
Chiller maintenance
Request this service
AC removal & refitting
Request this service
Duct cleaning & sanitising
Request this service
AC servicing by brand
Request this service
Operation & maintenance contracts
Request this service
AHU maintenance
Request this service
Fridge & freezer service
Request this service
Cold rooms
Request this service
Display fridges & chillers
Request this service
Factory HVAC
Request this service
Warehouse HVAC
Request this service
Villa & home HVAC
Request this service
Hotel HVAC
Request this service
School HVAC
Request this service
Hospital HVAC
Request this service
Mosque HVAC
Request this service
Mall & retail HVAC
Request this service
Restaurant & cafe HVAC
Request this service
Some of our work
Ductwork, rooftop units and diffusers, from work we've completed in Jeddah.
Customer reviews
What our customers say
- Muhammadramzan 2641
“MashaaAllah. Services are so good. Behaviour and kindness 100/100. Prices are less then Market. Fully recommended”
- shahzeb armani
“Wow. Prices are so comfortable. Outstanding services. People are so talented and nice”
- Tawfik AlyawerLocal Guide
“U can find all u need for air conditioning”
Your satisfaction matters to us! If you had a great experience with us, we'd love a 5-star rating and a kind review.
Worked with us? Leave a reviewService areas
We come to you anywhere in Jeddah
From Al Shiraa and Al Yaqout in the north to Al Thaghr and Al Quraiyat in the south, with our base in Al Aziziyah.

What sets this district apart
Al Baghdadiyah Al Sharqiyah is a relatively modern district of multi-storey buildings, many of them hotels, clinics and small hospitals that require reliable central AC systems. Hand-cutting ducts on site leaves gaps that leak cold air and increase condensation on interior surfaces because of the high humidity here. Pre-manufacturing ducts in the workshop with Foster sealant on every seam ensures no air leaks and even distribution of cooled air throughout the building's sections.
Al Baghdadiyah Al Sharqiyah lies in central Jeddah, a modern district of mixed-use multi-storey buildings both residential and commercial.
Most buildings here need supply and return ducts running long distances across multiple floors, requiring robust insulation to prevent cold loss.
The AC setup in Al Baghdadiyah Al Sharqiyah
- 1
Long multi-floor supply ducts
Residential and hotel buildings need vertical supply ducts spanning multiple floors, pre-manufactured with heavy insulation thickness.
- 2
Sealed return ducts to maintain duct pressure
Return ducts in central systems need Foster sealant on all joints to prevent warm outside air from entering the system.
- 3
Sections insulated with dense barrier material
Every duct section arrives fully insulated with condensation and heat-loss prevention material suited to this humid environment.
Before the visit
Before our visit in Al Baghdadiyah Al Sharqiyah
- 1
Confirm the number of floors and vertical distances
Give us the floor count and vertical distance between each level so we can manufacture the ducts to the correct lengths in the workshop.
- 2
Send the floor plan or a photo
Send a photo of the planned duct route or the floor plan via WhatsApp so we understand the system layout precisely.
- 3
Confirm the main unit and plenum locations
Tell us where the main unit and plenum will be positioned and their exact dimensions before manufacturing starts.
More districts for AC duct manufacturing
Other services in Al Baghdadiyah Al Sharqiyah
FAQ
Questions about AC duct manufacturing
How do you make sure the duct does not leak air at the seams?
We close the long seams with a tight mechanical lock as the sheet is formed, then seal every seam and every joint between sections with Foster sealant before insulating. Sections leave the workshop with matching flanges that tighten evenly when hung, because any small gap in cold duct means lost air and a point where condensation forms.
Does the duct arrive ready to hang, or is it assembled on site?
Sections arrive fabricated, insulated, sealed and numbered to the route drawing, so the fitters know where each piece goes without cutting or altering on site. What is left on site is joining the sections, fixing them to the hangers and connecting the unit and outlets, which shortens the work above the ceiling.
Do you make plenums for cassette and cabinet units?
Yes, we fabricate plenums for both types. A cassette unit plenum is measured to match the unit's outlet frame exactly so air reaches the branch runs without leaking at the connection. A cabinet unit plenum is made to carry both the supply and return paths if the design calls for it. Both types are insulated with Kimmco or Armaflex and sealed with Foster sealant before they leave the workshop.
Can you manufacture duct for a large commercial project?
Yes. The workshop is equipped to fabricate large supply and return trunk runs suited to commercial, government and industrial buildings. Each section is made to the project drawings, numbered and delivered ready to hang after insulation and sealing. When engineering drawings are available, the technical team reviews them before fabrication starts to confirm that the duct dimensions fit the ceiling voids on site.
Why are the duct sections insulated in the workshop before delivery?
The duct carries cold air through a ceiling void that may be hot and humid. Without external insulation, water vapour condenses on the cold sheet and drips onto the false ceiling or the goods below. So each section is wrapped in Kimmco or Armaflex in our workshop and every edge and joint is sealed with Foster sealant before delivery.
Our building spans multiple floors, how do you distribute cold air evenly?
We manufacture supply and return ducts to the correct lengths for the number of floors, with measured distribution openings on each level to ensure even airflow.
Can you install the ducts quickly without delaying the construction schedule?
We deliver the sections numbered and ready to hang immediately, so the crew fixes them without on-site cutting or modification, speeding up the project.
Jeddah's high humidity causes condensation on ducts, how do you handle this?
We fully insulate all ducts with moisture-barrier material, and every seam is sealed with Foster sealant to prevent humidity from entering the duct from outside.
The ducts run above suspended ceilings or within walls, how do you prevent air leaks in these tight spaces?
We select the correct duct sections for each cavity and seal every joint with Foster sealant before delivery, so there are no leaks even in tight wall spaces.