In Prince Fawaz North, south Jeddah, ducting in modern villas and apartment blocks requires routing through tight false ceilings and internal walls. Alrabih ensures every joint is sealed tightly and fully insulated for even cold-air distribution.
- Sealed joints
- Proper insulation
- Balanced branches
Clients We're Proud to Serve
Organisations and companies that trusted Alrabih with their projects.
When you need a specialist duct installer
- 1
Rooms that cool unevenly
One room freezing, another barely cool, even though they share the same system. The cause is usually a wrong branch takeoff or an unbalanced diffuser. We inspect the existing route and fix the fault at its real source, not at the thermostat.
- 2
Adding a room or a new wing
You have added a room or extended office space and need to connect it to the existing duct network. We inspect the current network to confirm it can carry the extension, then connect the new branch in a way that does not reduce airflow to the other rooms.
- 3
Air leaking above the false ceiling
You can hear air above the suspended ceiling, or some diffusers have grown weak since a previous maintenance visit. Unsealed joints waste cold air in the ceiling void before it reaches the rooms. Sealing them with Foster sealants solves the problem at its source.
Who it's for
Fitting out a new office that needs duct runs
We survey the ceiling voids before they are closed and route duct runs with correct hangers and branch takeoffs.
Ask on WhatsAppSome rooms barely cool and you suspect the duct
We inspect the duct route and fix wrong branch takeoffs and open joints at their exact location.
Ask on WhatsApp
What the work covers
- Duct routed above false ceiling
- Hangers and supports fitted
- Branch takeoffs and diffusers connected
- Joints sealed with Foster
- Duct insulated with Armaflex
How we work
How we work
- 1
Site survey
We inspect the ceiling void, plan a route clear of electrical and plumbing conflicts, and measure the actual dimensions of every section of the network.
- 2
Hang and route the duct
We fix hangers at correct spacing to prevent sag, then mount duct sections, connect branch takeoffs, and fit diffusers and grilles in the positions agreed at the survey.
- 3
Seal and insulate
We seal every joint with Foster sealants to stop air leakage, then insulate the duct with Armaflex or Kimmco to prevent condensation in Jeddah's humid air and keep the air cold along its full run.
- 4
Check and hand over
We run the system and confirm that air comes from every diffuser, then address any diffuser that seems weak before the false ceiling is closed and the site is handed over.
Planned routing or quick routing?
| Alrabih | The usual way | |
|---|---|---|
| Joints | Sealed with Foster sealants | Tape that fails in heat |
| Insulation | Full Armaflex or Kimmco | Patchy or missing |
| Hangers | Correct spacing, no sag | Too few, duct sags |
| Branch takeoffs | Positioned to balance airflow | Wherever space allows |
| Duct route | Planned at survey | Decided on site |
Everything your AC needs, from one team
From system design and duct fabrication to installation, commissioning and maintenance.

Split AC installation
Request this service
Duct installation
Request this service
Central AC installation
Request this service
Duct fabrication
Request this service
Cold room installation
Request this service
Electro-mechanical works
Request this service
Chiller & AHU installation
Request this service
HVAC design
Request this service
AC repair & faults
Request this service
AC cleaning
Request this service
Refrigerant charging
Request this service
Central AC maintenance
Request this service
Chiller maintenance
Request this service
AC removal & refitting
Request this service
Duct cleaning & sanitising
Request this service
AC servicing by brand
Request this service
Operation & maintenance contracts
Request this service
AHU maintenance
Request this service
Fridge & freezer service
Request this service
Cold rooms
Request this service
Display fridges & chillers
Request this service
Factory HVAC
Request this service
Warehouse HVAC
Request this service
Villa & home HVAC
Request this service
Hotel HVAC
Request this service
School HVAC
Request this service
Hospital HVAC
Request this service
Mosque HVAC
Request this service
Mall & retail HVAC
Request this service
Restaurant & cafe HVAC
Request this service
Some of our work
Ductwork, rooftop units and diffusers, from work we've completed in Jeddah.
Customer reviews
What our customers say
- Muhammadramzan 2641
“MashaaAllah. Services are so good. Behaviour and kindness 100/100. Prices are less then Market. Fully recommended”
- shahzeb armani
“Wow. Prices are so comfortable. Outstanding services. People are so talented and nice”
- Tawfik AlyawerLocal Guide
“U can find all u need for air conditioning”
Your satisfaction matters to us! If you had a great experience with us, we'd love a 5-star rating and a kind review.
Worked with us? Leave a reviewService areas
We come to you anywhere in Jeddah
From Al Shiraa and Al Yaqout in the north to Al Thaghr and Al Quraiyat in the south, with our base in Al Aziziyah.

What sets this district apart
Prince Fawaz North is a modern district mixing individual villas with medium-rise apartment blocks and contemporary interiors with uniform false ceilings. Ducts here often run through tight gaps between ceilings and load-bearing walls, and any leak or poor branch seal causes pressure loss and uneven flow. Thermal insulation and precise hanger fastening are essential because false ceilings trap heat during the long summer.
Prince Fawaz North sits in south Jeddah, a district of modern villas and contemporary apartment blocks with planned urban layout.
Most homes and flats here have false ceilings of roughly uniform height, which simplifies duct routing but requires precise spacing calculations.
The AC setup in Prince Fawaz North
- 1
Main duct and branches in tight false ceiling
The main duct runs carefully through the height-limited false ceiling and branches to each room at a diameter calculated to avoid friction and excess pressure.
- 2
Flexible branches for directional changes in confined spaces
In flats and tight spaces, we use flexible branches to change duct direction smoothly without weakening airflow.
- 3
Thick insulation against heat gain from false ceiling
The duct is wrapped with extra-thick Armaflex because the false ceiling traps summer heat, essential to maintain cool air temperature.
Before the visit
Before our visit in Prince Fawaz North
- 1
Confirm false-ceiling height and available space
Measure the false-ceiling height and tell us about any obstacles like ventilation pipes or cables before our visit.
- 2
Provide a map of water and electrical lines in the flat
Get a diagram showing water and electrical routes in walls and ceiling so we can safely avoid them.
- 3
Coordinate with building management or flat owner
Alert building management or neighbouring units in advance, as installation involves drilling and fastening noise.
More districts for Duct installation
Other services in Prince Fawaz North
FAQ
Questions about Duct installation
How do you know the existing network can carry an extension?
Before any extension the technician checks the main duct dimensions and existing branch takeoffs, and measures air velocity at the current diffusers. If velocity is already low or the main run is narrow, he explains what must be corrected first. The site survey determines whether the extension is feasible on the existing network or whether the supply section needs to be enlarged.
Why does moisture form on the duct above the false ceiling?
Warm humid air trapped above the false ceiling meets the cold duct surface and moisture condenses on the outside of the duct wall. The most common cause is torn insulation or open joints that let warm air reach the bare metal. Armaflex or Kimmco insulation is fitted around the full perimeter and every joint is sealed with Foster sealants so no path remains for outside air to reach the duct surface.
Can you re-hang sagging duct without replacing the whole network?
Usually yes. The technician first identifies the cause of the sag: a failed hanger, a loose anchor point in the ceiling structure, or deformation of the duct itself. If the duct is undamaged, hangers are repositioned and spaced to prevent the sag from recurring. If the duct is deformed or the insulation has failed, the technician explains what needs replacing before re-hanging proceeds.
When is a damper needed at a branch takeoff?
A damper is fitted at a branch takeoff when the cooling load differs between zones connected to the same main duct run, for example a room with a large window compared with an interior corridor. Without a damper the path of least resistance takes most of the air and the other rooms receive less. The site survey identifies which branch points require a damper and which can be balanced by adjusting the takeoff size alone.
Can duct runs be extended after the false ceiling is closed?
It is usually possible by opening access panels or cutting limited sections in the false ceiling to reach the void above. The technician maps the route before starting to keep the number of openings to a minimum. Once the duct run, insulation and sealing are complete, panels are refitted or the cut sections are restored. The complexity and number of openings depend on the false ceiling type and any obstructions present, which the site survey establishes.
My flat is in a building, can you fit central ducting in the tight space above the false ceiling?
Yes, if the height allows. We inspect the space first, choose a smaller duct diameter if needed, and plan the route to avoid existing cables and pipes.
The flat is tight and walls are full of pipes, how do you run the duct safely?
We map existing pipes before drilling or fastening, choose routes away from plumbing and electrics, and use strong hangers for all branches.
Summer heat is intense here, does the duct lose coldness quickly?
Yes, cold air in the false ceiling gains heat quickly. We wrap the duct with thick Armaflex to slow heat gain and maintain temperature to the diffusers.
The flat's main power line is weak, can it run the duct fans and compressor?
It depends on the line capacity and total load. We inspect existing wiring and advise you before installation whether a separate circuit or upgrade is needed.