Duct insulation in Al Farouq, Jeddah

In Al Farouq in south Jeddah, modern residential buildings and mixed-use projects rely on central AC with insulated ductwork. We wrap the pipes with glass wool and seal joints with a vapour barrier to protect the structure and false ceilings from coastal dampness.

4.9 on Google
  • Glass-wool wrap
  • Vapour seal
  • No condensation

Clients We're Proud to Serve

Organisations and companies that trusted Alrabih with their projects.

  • Saudi Aramco
  • Ministry of Energy
  • Royal Saudi Land Forces
  • Royal Saudi Naval Forces
  • Al Baik
  • Centro Hotels by Rotana
  • King Abdullah Economic City
  • First Mills
  • Juffali
  • eXtra
  • Dr. Soliman Fakeeh Medical Center
  • Alesayi Motors
  • Abu Zaid
  • Water Desalination
  • Attieh Steel
  • SSCO
  • Creet
  • Emad Rizq
  • Alfaneyah
  • Rawat Alam Al Tasmeem
  • IBI Magix Arabia, Construction Services
  • Midtown for Construction
  • Petra Engineering Industries Co.
  • Hyrmas
  • Batterjee Medical College
  • Advanced Horizons Contracting Company
  • D.Metals
  • Benchbox, Masters of Space
  • Sadafco
  • Umm Al-Qura University
  • Saudi Arabian Drug Store (SADS)
  • Foamco
  • Ahmad A. R. Bin Afif Industries Co. (Sandwich Panel Factory)
  • Namariq
  • ALS

Is it for you?

When duct insulation becomes urgent

  1. 1

    Damp patches on the false ceiling

    Damp stains or drips under the false ceiling in summer usually mean cold duct with no proper insulation. Humid air touches the cold metal, condenses, falls onto the ceiling boards and ruins the plaster and paint.

  2. 2

    Old, cracked or loose insulation

    Insulation that has cracked, pulled away from the metal or been soaked by a past leak no longer stops vapour. Even a small gap between two sections is enough for moisture to condense on the metal and restart the dripping problem.

  3. 3

    New duct you want fully insulated

    When new air ducts are installed in a home or commercial building, insulation is part of the work, not an afterthought. We wrap the duct and seal the joints before the ceiling is closed so it never needs to be opened again for this reason.

Who it's for

  • Noticing damp patches on your room ceiling

    We survey the duct, wrap it in glass-wool and seal every joint so condensation stops completely.

    Ask on WhatsApp
  • Installing new duct in a commercial building

    We wrap the duct in glass-wool and seal all joints before the ceiling closes, with a one-year warranty.

    Ask on WhatsApp

What the job covers

What the insulation work covers

  • Duct route and insulation survey
  • Glass-wool wrap over duct
  • Vapour-sealed joints and corners
  • Plenum box and connections insulated
  • Fixed with correct fasteners
Request a quote

How we work

How we work

  1. 1

    Ceiling and duct survey

    The technician inspects the duct route and any existing insulation, then marks the sections that need new wrapping or re-insulation before work begins.

  2. 2

    Surface prep and strip-out

    Damaged or wet insulation is stripped off and the metal surface cleaned so the new material bonds properly with no air pockets trapped beneath.

  3. 3

    Wrap and seal

    We wrap the duct in glass-wool and cover every joint, corner and connection with the correct vapour barrier, using Foster, Armaflex or Kimmco sealing materials as the site requires.

  4. 4

    Check and handover

    The technician checks the insulation along the full route, confirms the wrap is secure and joints are gap-free, then hands over the completed work with a one-year warranty and competitive prices.

Start with step one

Why Alrabih?

Sealed insulation or a surface cover?

AlrabihThe usual way
Vapour barrierSealed at every joint and cornerLeft open or incomplete
Joins between sectionsClosed with correct sealantTape that peels off
Plenum box and connectionsInsulated with the restSometimes left bare
Drips after fittingStops when sealing is correctReturns within weeks
Sheet materialG90 galvanized sheet from SABICSheet of unspecified grade
Request a quote

Everything your AC needs, from one team

From system design and duct fabrication to installation, commissioning and maintenance.

Some of our work

Ductwork, rooftop units and diffusers, from work we've completed.

  • Galvanized rectangular duct trunk with branch takeoffs and round diffusers, hung from a black ceiling, a Carrier unit visible behind — interior finishing stage.
  • Round diffusers and a spiral duct trunk in a tiled stairwell service shaft.
  • Rooftop ductwork and an exhaust fan, with Jeddah buildings in the background.
  • Rooftop packaged AC units with rectangular duct transitions, city buildings behind.
  • Insulated rooftop duct run beside a packaged unit, a warehouse roof in the background.
  • A grid of round diffusers in an open-plan office ceiling, mid-construction.
  • An insulated rooftop duct elbow, against a mountainous backdrop.
  • Large insulated ductwork running along a factory ceiling, with workers visible below.
  • A yellow round diffuser mid-installation, with spiral duct and a suspended ceiling grid.
  • Duct insulation wrap in progress on a construction site, bare duct still exposed.
  • A black-painted duct trunk with round diffusers and track lighting, in a finished retail interior.
  • An indoor AHU unit connected to round ductwork in a mechanical plant room, exposed concrete ceiling.
Browse all our work Similar project? Send us the details

Customer reviews

What our customers say

4.9

From 21 Google reviews

  • Waleed Daadouch

    “The nicest treatment from the showroom team, and their prices are very competitive.”

    Translated from Arabic

  • Muhammadramzan 2641

    “MashaaAllah. Services are so good. Behaviour and kindness 100/100. Prices are less then Market. Fully recommended”

  • RHAM rhamLocal Guide

    “May God grant them success. Refined and respectful treatment.”

    Translated from Arabic

  • shahzeb armani

    “Wow. Prices are so comfortable. Outstanding services. People are so talented and nice”

  • Shakeel Ahmed

    “Nice experience very cooperative. Nice conducting with all customers”

  • Tawfik AlyawerLocal Guide

    “U can find all u need for air conditioning”

Read every review on Google

Your satisfaction matters to us! If you had a great experience with us, we'd love a 5-star rating and a kind review.

Worked with us? Leave a review

Service areas

We come to you anywhere in Jeddah

From Al Shiraa and Al Yaqout in the north to Al Thaghr and Al Quraiyat in the south, with our base in Al Aziziyah.

Map of Jeddah by sector, with Alrabih's base in Al Aziziyah
Don't see your district?Message us. We most likely cover it.

What sets this district apart

Al Farouq is a relatively modern growth district with multi-storey apartment buildings and mixed-use projects combining residential and commercial use. Metal ductwork in these projects suffers from coastal humidity and salty air, especially where running through partially exposed cavities or building roofs. Glass insulation with a vapour barrier protects false ceilings and extends the life of the entire system.

Al Farouq in south Jeddah is a modern growth district with mixed residential and commercial apartment buildings.

Mixed residential and commercial projects here use a single central AC system with insulated duct serving both flats and commercial spaces.

The AC setup in Al Farouq

  1. 1

    Insulated metal duct in ceiling and wall cavities

    Most mixed-use projects hide the main duct in false ceiling and interior wall cavities, where it needs tight insulation.

  2. 2

    Separate flexible ducts for flats and shops

    Each flat or shop has its own separate flexible duct from the main duct with its own outlet, each independently insulated.

  3. 3

    Central plenum box serving all flats and shops

    The single plenum box collects cold air from the main AC units and distributes it through the main and branch duct to all units.

Before the visit

Before our visit in Al Farouq

  1. 1

    Get design drawings for all cavities and zones

    Ask the engineer for detailed drawings of ceiling cavities, main and branch duct routes, and outlet locations for each flat and shop.

  2. 2

    Confirm coordination of duct with electrical and plumbing

    Check that the duct route does not conflict with existing electrical cables or water pipes in the same cavities.

  3. 3

    Coordinate with all owners in the mixed-use project

    If the project has both flats and shops, ensure all owners agree on the installation schedule before starting work.

FAQ

Questions about Duct insulation

Why does duct sweat more in Jeddah than in other places?

Jeddah combines intense heat with high humidity, especially near the coast. Cold air inside the duct chills the metal, and the warm humid air outside condenses on it immediately if there is no insulation keeping vapour away from the metal surface.

Can duct be insulated after the false ceiling is closed?

It depends on the size of existing access hatches and the duct route. In some areas the work can be done through the hatches already there; in others a section of ceiling needs to be opened. The survey decides the right approach before any work starts.

What is the difference between Armaflex, Kimmco and Foster for duct insulation?

Armaflex and Kimmco are flexible insulation materials used for wrapping duct and reducing condensation. Foster is a sealant applied to joints and connections to block vapour from passing through. We choose the right material for each part of the duct after the site survey, and may use more than one on a single project.

Do you insulate duct in commercial and industrial projects too?

Yes, we work in residential, commercial, industrial and government buildings across all Jeddah districts. Project size affects quantities and coordination with other trades, which the survey maps out. Discounts by quantity and project size apply to larger works.

Does the plenum box need different insulation from the rest of the duct?

The plenum box has a larger surface area and cools quickly in Jeddah's humid air, making it especially prone to condensation. The technician wraps it in glass-wool and seals its corners and openings with the correct vapour barrier. The sealant chosen may differ from the one used on the rest of the duct route, depending on what the survey finds.

Mixed residential and commercial projects, do they need one duct or separate ones?

Either a single duct with separate dampers for each zone, or separate ductwork for each use, is possible. We agree with the engineer on the best option based on the design.

Partially exposed roofs open to wind and salt spray, does that affect the insulation?

Yes, salty air penetrates any gap in the insulation, so we seal every joint and edge with a tight vapour barrier that protects the duct and insulation.

How do you handle copper pipes if they run in the same cavities?

We fit separate heat insulation on copper pipes to prevent heat loss and avoid any interaction with the duct's glass insulation.

Flats and shops are close together, how do you balance different cooling needs?

We fit separate thermostats and dampers in each zone so each owner controls the temperature in their unit independently without affecting others.

The Jeddah corniche in cool weather

Stop the duct dripping for good

WhatsApp us a photo of the false ceiling or bare duct and we will arrange a survey in your district, Saturday to Thursday, eight in the morning to eight in the evening.