Cooling fit for a mosque
Mosque HVAC in Al Fanar
Mosque HVAC in Al Fanar, Jeddah's far north, faces unique climate challenges from high humidity and salt air. Alrabih designs robust cooling systems with strong corrosion and moisture protection for long-term reliability.
- Even distribution
- Quiet units
- Scheduled servicing
Clients We're Proud to Serve
Organisations and companies that trusted Alrabih with their projects.
When a mosque needs a specialist approach
- 1
Heat reaching the back rows
Cold air pools near the units and never reaches the back of the hall. In Jeddah's humidity, worshippers in the far rows feel the heat even with the system running. That is a design problem, not a unit fault.
- 2
Noise that disturbs prayer
Unit noise in a quiet hall distracts worshippers and breaks concentration. The right unit type, its position and the air velocity setting all reduce noise to the lowest possible level, and those choices are made at the survey.
- 3
A dome or high ceiling that traps heat
Hot air rises and collects under the dome, so the breathing level stays warm even with large units running. We set diffuser angles and air paths at the survey to push that hot layer out rather than cool over the top of it.
Who it's for
Building a new mosque that needs AC from the start
We join the design stage to fix duct routes and unit positions before ceilings are closed, so the installation is clean and efficient with no remedial work needed later.
Ask on WhatsAppYour existing mosque cools unevenly across the rows
We survey the existing system, find the cause of uneven distribution and propose changes to the airflow paths or units without disrupting the mosque.
Ask on WhatsApp
What the work covers
- Hall survey and airflow mapping
- Ductwork to SMACNA standard
- Units fitted at surveyed positions
- Airflow check across the rows
- Contracts scheduled between prayers
How we work
How we work
- 1
Mosque survey
We visit the mosque outside prayer times to measure the hall, ceiling height and dome, and agree diffuser positions, duct routes and unit locations before any work begins.
- 2
Design and fabrication
We design the system from the survey data and fabricate the ducts in our own workshop from G90 galvanised sheet, then prepare them for installation.
- 3
Installation at agreed times
We coordinate with mosque management to work between prayers or at times that do not interrupt activities, and we leave the hall clean at the end of each working day.
- 4
Testing and handover
We run the system and measure air distribution at the front and back rows and sound levels, adjusting the balance until comfort is even across the whole hall.
Designed for a mosque or units placed at random?
| Alrabih | The usual way | |
|---|---|---|
| Air distribution | Even across every row | Cold front, hot back |
| Sound | Assessed at survey | Not considered |
| Dome and high ceiling | Planned airflow paths | Hot layer left above |
| Maintenance | Scheduled between prayers | Visits that disrupt use |
| Startup scheduling | Programmed before each prayer | Manual, inconsistent start |
Everything your AC needs, from one team
From system design and duct fabrication to installation, commissioning and maintenance.

Split AC installation
Request this service
Duct installation
Request this service
Central AC installation
Request this service
Duct fabrication
Request this service
Cold room installation
Request this service
Electro-mechanical works
Request this service
Chiller & AHU installation
Request this service
HVAC design
Request this service
AC repair & faults
Request this service
AC cleaning
Request this service
Refrigerant charging
Request this service
Central AC maintenance
Request this service
Chiller maintenance
Request this service
AC removal & refitting
Request this service
Duct cleaning & sanitising
Request this service
AC servicing by brand
Request this service
Operation & maintenance contracts
Request this service
AHU maintenance
Request this service
Fridge & freezer service
Request this service
Cold rooms
Request this service
Display fridges & chillers
Request this service
Factory HVAC
Request this service
Warehouse HVAC
Request this service
Villa & home HVAC
Request this service
Hotel HVAC
Request this service
School HVAC
Request this service
Hospital HVAC
Request this service
Mosque HVAC
Request this service
Mall & retail HVAC
Request this service
Restaurant & cafe HVAC
Request this service
Some of our work
Ductwork, rooftop units and diffusers, from work we've completed in Jeddah.
Customer reviews
What our customers say
- Muhammadramzan 2641
“MashaaAllah. Services are so good. Behaviour and kindness 100/100. Prices are less then Market. Fully recommended”
- shahzeb armani
“Wow. Prices are so comfortable. Outstanding services. People are so talented and nice”
- Tawfik AlyawerLocal Guide
“U can find all u need for air conditioning”
Your satisfaction matters to us! If you had a great experience with us, we'd love a 5-star rating and a kind review.
Worked with us? Leave a reviewService areas
We come to you anywhere in Jeddah
From Al Shiraa and Al Yaqout in the north to Al Thaghr and Al Quraiyat in the south, with our base in Al Aziziyah.

What sets this district apart
Al Fanar is a coastal district in Jeddah's far north, very close to the sea and beaches, with high humidity and salt in the air year-round. Mosques here face faster corrosion of outdoor units and metal ducts from salt exposure, and condensation and mould appear quickly in ducts and electrical switches. We choose corrosion-resistant materials, carefully monitor drainage and ventilation, and plan short maintenance intervals to prevent moisture and salt buildup.
Al Fanar sits at Jeddah's far north on the coast, a seaside district with mosques very close to the sea.
Al Fanar mosques need central cooling units with rust and salt-resistant materials, and drainage pipes must be robust and easy to clean to withstand high humidity effects.
The AC setup in Al Fanar
- 1
Central unit with salt-resistant materials
The central unit is made from rust and salt-resistant materials, with extra protective coatings on coils and fans against marine corrosion.
- 2
Ducts with mould-resistant linings
Ducts are lined with mould and moisture-resistant material, preventing bacterial and fungal buildup in distributed air.
- 3
Robust, easily accessible drainage system
Drainage pipes are properly sealed and angled to avoid water trapping, with easy access for regular cleaning of salt deposits and residue.
Before the visit
Before our visit in Al Fanar
- 1
Survey outdoor unit location near the sea
We inspect the proposed outdoor unit location to ensure minimum direct exposure to salt spray and strong winds from the sea.
- 2
Confirm safe condensate drainage points
We verify that drainage pipes reach a safe location away from walls and intakes, without causing seepage or water pooling near foundations.
- 3
Document the shorter maintenance schedule
We agree with mosque management on an intensive maintenance schedule every one or two months to clean coils and ducts of salt and mould.
More districts for Mosque HVAC
Other services in Al Fanar
FAQ
Questions about Mosque HVAC
How do you make sure the far rows get enough cooling?
At the survey we set diffuser angles, air velocity and duct routing so cold air travels to the last row. After installation we measure the temperature difference between the front and back rows and adjust each diffuser's balance until that difference is as small as the space allows.
Can you work in a functioning mosque without disrupting prayers?
Yes. We agree a phased schedule with mosque management in advance and divide the work into sessions between prayers. Before each call to prayer we lift tools, cover any temporary openings and return the hall to a usable state, then resume afterwards.
What type of ductwork do you use in prayer halls?
We fabricate ducts in our own workshop from G90 galvanised sheet, round or rectangular as the design requires. We use Armaflex and Kimmco insulation and Foster sealants to limit heat gain and keep sound transmission through the ductwork as low as possible.
Can the system be set to start just before each prayer time?
Yes. The controls on Carrier, YORK, General, Midea, Gree and Smart Gold units support scheduled start and stop times. At the survey we confirm the scheduling options for the chosen units and programme the timings at handover, so the hall is already cool when worshippers arrive.
Can we cool only part of the hall when fewer people attend?
Yes, if the system is designed in zones. We divide the hall into sections, each with its own unit or closable outlets, so you run the front rows alone when few people attend and the whole hall for Friday prayer and occasions, cutting power use without affecting worshippers.
Salt and coastal humidity cause corrosion; how do you protect the units?
We choose units with corrosion-resistant materials such as aluminium and galvanised steel, and coat exposed metals with extra anti-corrosion layers.
High humidity causes mould in ducts; is there a solution?
We choose ducts with mould-resistant linings, ensure fast and complete condensate drainage, and recommend short maintenance intervals to clean accumulated moisture from ducts.
The sea is very close to the mosque; does salt spray affect the AC?
Yes, salt spray deposits on coils and fans, reducing efficiency, so we choose units with protected coils and increase maintenance and cleaning frequency.
How often do we need maintenance in such a coastal environment?
We recommend maintenance every one to two months instead of three, to clean coils and ducts of salt and mould and monitor drainage condition.