Restaurant & cafe HVAC in Jazan, Jazan Region

Restaurant and cafe HVAC in Jazan faces a double challenge: the Red Sea's heat and humidity plus the salt air that finds its way into coils, and the need to balance a hot kitchen against a dining room that stays cool when full. Our design isolates the kitchen, delivers cold air to the guests, and pulls moisture and odours away before they reach the tables.

4.9 on Google
  • Pressure balance
  • Make-up air
  • Coil protection

Clients We're Proud to Serve

Organisations and companies that trusted Alrabih with their projects.

  • Saudi Aramco
  • Ministry of Energy
  • Royal Saudi Land Forces
  • Royal Saudi Naval Forces
  • Al Baik
  • Centro Hotels by Rotana
  • King Abdullah Economic City
  • First Mills
  • Juffali
  • eXtra
  • Dr. Soliman Fakeeh Medical Center
  • Alesayi Motors
  • Abu Zaid
  • Water Desalination
  • Attieh Steel
  • SSCO
  • Creet
  • Emad Rizq
  • Alfaneyah
  • Rawat Alam Al Tasmeem
  • IBI Magix Arabia, Construction Services
  • Midtown for Construction
  • Petra Engineering Industries Co.
  • Hyrmas
  • Batterjee Medical College
  • Advanced Horizons Contracting Company
  • D.Metals
  • Benchbox, Masters of Space
  • Sadafco
  • Umm Al-Qura University
  • Saudi Arabian Drug Store (SADS)
  • Foamco
  • Ahmad A. R. Bin Afif Industries Co. (Sandwich Panel Factory)
  • Namariq
  • ALS

Is it for you?

When your restaurant needs a specialist

  1. 1

    Kitchen smells reaching diners

    When the extract hood pulls out more air than is replaced, the kitchen goes negative and draws air from the dining room, bringing smells with it. The answer is calculating the volumes and delivering make-up air close to the hood.

  2. 2

    Dining room stays warm despite the AC

    A full dining room raises the heat load noticeably, and design must account for the building's conditions and its city's climate at peak occupancy. The right diffuser layout achieves even cooling across tables, not cold near the duct and warm in the corners.

  3. 3

    Repeated breakdowns in kitchen AC units

    Grease vapour from the burners settles on evaporator coils and blocks airflow, raising pressure and stressing the compressor. Placing the unit away from grease currents and scheduling coil cleaning reduces this damage significantly.

Who it's for

  • Opening a new restaurant that needs a full HVAC system

    We design the cooling and make-up air system from scratch to match your kitchen and dining layout before you open.

    Ask on WhatsApp
  • Your restaurant is running but smells are reaching the tables

    We survey the existing system, measure pressure between kitchen and dining, then correct the fault by adding make-up air or adjusting the air balance.

    Ask on WhatsApp

What the job covers

What the work covers

  • Kitchen and dining pressure survey
  • Make-up air for hood
  • Diffuser layout for dining
  • Ductwork to SMACNA standards
  • Air balance commissioning
Request a quote

How we work

How we work

  1. 1

    Site and kitchen survey

    We visit, measure the spaces, review the existing extract hood and burner positions, and find where negative pressure is occurring before any design work.

  2. 2

    Design and equipment selection

    We design the make-up air and cooling systems together, and select units from Carrier, YORK, General, Midea, Gree or Smart Gold to suit the space and the load.

  3. 3

    Duct fabrication and installation

    We fabricate ducts in our workshop from G90 galvanised sheet to precise sizes, install the units, and insulate the pipework with Armaflex. We supply copper runs of up to 30 metres without welded joints.

  4. 4

    Balancing and handover

    We run the system and adjust dampers until the kitchen sits at slight negative and the dining room at slight positive, confirming that doors open easily and no kitchen smell crosses to the guests.

Start with step one

Why Alrabih?

Integrated design or separate units with no balance?

AlrabihThe usual way
Make-up airCalculated and delivered to the hoodUsually not addressed
Dining pressureSlight positive, no smell transferNegative, pulls kitchen air in
Coil protectionUnit placed away from greaseRepeated breakdowns
Cooling spreadDiffusers sized for full occupancyUneven, warm corners
Kitchen ductworkFabricated in-house from G90 sheetOff-the-shelf sizes, poor fit
Request a quote

Everything your AC needs, from one team

From system design and duct fabrication to installation, commissioning and maintenance.

Some of our work

Ductwork, rooftop units and diffusers, from work we have completed.

  • Galvanized rectangular duct trunk with branch takeoffs and round diffusers, hung from a black ceiling, a Carrier unit visible behind — interior finishing stage.
  • Round diffusers and a spiral duct trunk in a tiled stairwell service shaft.
  • Rooftop packaged AC units with rectangular duct transitions, city buildings behind.
  • Insulated rooftop duct run beside a packaged unit, a warehouse roof in the background.
  • A grid of round diffusers in an open-plan office ceiling, mid-construction.
  • An insulated rooftop duct elbow, against a mountainous backdrop.
  • Large insulated ductwork running along a factory ceiling, with workers visible below.
  • A yellow round diffuser mid-installation, with spiral duct and a suspended ceiling grid.
  • Duct insulation wrap in progress on a construction site, bare duct still exposed.
  • A black-painted duct trunk with round diffusers and track lighting, in a finished retail interior.
  • An indoor AHU unit connected to round ductwork in a mechanical plant room, exposed concrete ceiling.
Browse all our work Similar project? Send us the details

Customer reviews

What our customers say

4.9

From 21 Google reviews

  • Waleed Daadouch

    “The nicest treatment from the showroom team, and their prices are very competitive.”

    Translated from Arabic

  • Muhammadramzan 2641

    “MashaaAllah. Services are so good. Behaviour and kindness 100/100. Prices are less then Market. Fully recommended”

  • RHAM rhamLocal Guide

    “May God grant them success. Refined and respectful treatment.”

    Translated from Arabic

  • shahzeb armani

    “Wow. Prices are so comfortable. Outstanding services. People are so talented and nice”

  • Shakeel Ahmed

    “Nice experience very cooperative. Nice conducting with all customers”

  • Tawfik AlyawerLocal Guide

    “U can find all u need for air conditioning”

Read every review on Google

Your satisfaction matters to us! If you had a great experience with us, we'd love a 5-star rating and a kind review.

Worked with us? Leave a review

Where we work

Restaurant & cafe HVAC in cities near Jazan

We are based in Jeddah, and we supply duct and install across the Kingdom. All our services in Jazan

What sets this city apart

Restaurants and cafes in Jazan spread across beachfront hotels, units in the city's shopping malls and smaller eateries in residential neighbourhoods. In every case the kitchen radiates intense heat and humid air carries cooking smells and steam into the surrounding space. HVAC design must keep the kitchen cool enough to preserve food, pull smoke and moisture forcefully from the hood towards the outside, and pump clean cold air to the dining room right up to the doors so they do not open and let Jazan's humidity seep in.

Jazan is a port city on the southern Red Sea coastal plain, hot and humid for most of the year with sea salt thick in the air.

In Jazan's coastal restaurants, condenser units sit on roofs or sea-facing walls, and salt-laden air requires periodic cleaning of the heat exchangers.

All our services in Jazan

The AC setup in Jazan

  1. 1

    High-capacity kitchen exhaust hood

    Hot humid kitchens in Jazan need a strong hood that pulls heat, steam and cooking smells quickly to a direct outdoor vent.

  2. 2

    Make-up air for the dining room

    The hood exhaust drops pressure in the kitchen, so we pump extra cold air to the dining room and entrance so doors do not swing open and let in sea moisture.

  3. 3

    Salt protection for outdoor condensers

    Condenser units on roofs or sea-facing walls need regular cleaning, and placement is decided after the site survey to reduce direct exposure to salt spray.

Before the visit

Before our visit in Jazan

  1. 1

    Send a sketch of the kitchen and dining area

    Send a photo or sketch showing the hood, entrance, doors and windows so we can estimate air pressure balance and distances before we visit.

  2. 2

    Choose where the condensers sit

    Agree with the restaurant owner or building manager where the outdoor units go on the roof or exterior wall, because it sets the copper run length and salt exposure.

  3. 3

    Arrange duct and pipe routing into the space

    Tell us how and where the duct and piping can enter the kitchen and dining area without disrupting operations or disturbing guests during installation.

FAQ

Questions about Restaurant & cafe HVAC

What is the difference between make-up air and kitchen air conditioning?

Make-up air replaces the volume the hood extracts, its purpose is pressure balance not necessarily cooling. Kitchen air conditioning tackles burner heat and lowers temperature for the staff. Both may be needed, and the site survey determines which your kitchen requires.

Do outdoor seating areas need a different approach?

Yes. Fans alone are not enough during peak months in most Saudi cities. The right option depends on whether the space has an open roof or a partial enclosure and how large the area is. We assess the spot and propose suitable units after the site survey.

How are AC coils protected from kitchen grease?

The first step is design: we position kitchen units in airflow paths away from the grease rising off the burners. In preventive maintenance contracts we schedule pressure coil cleaning before build-up raises stress on the compressor, because early cleaning is simpler and less costly than a repair.

Can existing ductwork in an operating restaurant be repaired or does it need replacing?

The decision follows a duct inspection: we look for air leaks, grease build-up inside, and sheet corrosion assessed against the building's conditions and its city's climate. If the structure is sound we seal joints with Foster sealants and re-insulate with Kimmco. If not, we fabricate new sections in our workshop and replace the damaged runs.

Does a packed dining room during peak season affect how the AC performs?

Yes, every person in the room adds heat, and this effect is more pronounced during peak season when temperatures are high. Design therefore accounts for full occupancy load, not average attendance, and diffusers are positioned to deliver even cooling across all tables. The exact layout is confirmed after the site survey.

Do you install separate HVAC for the kitchen and dining room in Jazan restaurants?

Yes. The kitchen needs higher-capacity indoor units and a strong hood to extract heat, smoke and moisture, while the dining room gets a separate distribution that keeps cold clean air reaching guests without smell crossover.

How does the HVAC system reach my restaurant in Jazan from your workshop?

We visit your restaurant in Jazan, measure and survey, design the system, supply indoor and outdoor units, duct and copper from our Jeddah base, and coordinate delivery and installation with you as set out in the quote.

Do Jazan's sea salt and humidity damage the units?

Salt and humidity accelerate corrosion on heat exchangers and copper piping, so we choose units and positions after surveying your site and protect the copper runs and joints against salt exposure where we can.

Must the hood exhaust duct lead straight outside from the kitchen?

Yes. The hood pulls smoke, steam and cooking smells straight outside through a separate duct, not into the main HVAC, so the dining-room air stays clean and grease does not build up in the duct coils.

Keep your dining room away from the kitchen

WhatsApp a floor plan or photos of your kitchen and dining room and we will arrange a survey in your district, Saturday to Thursday, eight in the morning to eight at night.

CallWhatsApp