Tower and office building HVAC in Al Kandarah, Jeddah
In Al Kandarah, mixed office and residential towers need balanced central HVAC systems distributing air through organized ducts. Alrabih designs systems where each unit controls its temperature independently without affecting other units in the same tower.
4.9 on Google- Zone control
- Vertical risers
- Per-floor zoning
Clients We're Proud to Serve
Organisations and companies that trusted Alrabih with their projects.
Is it for you?
When your building needs a specialist contractor
- 1
New office tower under construction
The hardest part is coordinating with the main contractor: fixing riser shafts and floor penetrations before concrete is poured, locating plant rooms on the right floors, and documenting everything before walls are closed.
- 2
Existing building needing a system upgrade
The old system no longer serves the current tenant load, energy losses are high, or some floors stay warm in Jeddah's humid heat with no one knowing where the fault starts. A detailed survey identifies the path forward.
- 3
New tenant redesigning their floor
Moving partition walls means relocating air outlets and dampers for every new office. A zone designed carefully lets you add the tenant without upsetting the air balance across the rest of the building.
Who it's for
Your office tower is under construction now
We coordinate with the main contractor to fix riser shafts, floor penetrations and plant room positions before walls are closed and concrete is poured.
Ask on WhatsAppYou manage an occupied office building with complaints
We survey the existing network floor by floor, identify why airflow is unbalanced across zones, and carry out corrections in phases without cutting cooling to neighbouring offices.
Ask on WhatsApp
What the job covers
What our scope covers
- Duct network design
- G90 sheet to SMACNA
- Zone layout and dampers
- Flexible connections and plenums
- Commissioning and air balancing
How we work
How we work
- 1
Survey and drawing review
We visit the site and review the architectural and structural drawings, fixing riser routes, plant room positions and floor penetrations in coordination with the project team.
- 2
Design and zone layout
We design the duct network, assign zones per floor and tenant, and set duct sizes, damper positions and plenum box locations for every branch.
- 3
Duct fabrication and installation
We fabricate ducts in our workshop from G90 galvanized sheet to SMACNA standards, insulate them with glass-wool, and install floor by floor in coordination with other contractors on site.
- 4
Balancing and handover
After start-up we balance airflow across all air outlets, verify each thermostat responds correctly, and hand the as-built drawings to the building management.
Why Alrabih?
Integrated design or unplanned expansion?
| Alrabih | The usual way | |
|---|---|---|
| Zone layout | Designed per floor and tenant | Estimated without design |
| Ductwork | Fabricated to calculated sizes | Random sizes used |
| Dampers | On every branch for control | Fitted where convenient |
| As-built record | Final drawings handed over | No record after handover |
| Riser insulation | Glass-wool stops condensation | Insulation skipped |
Everything your AC needs, from one team
From system design and duct fabrication to installation, commissioning and maintenance.

Split AC installation
Request this service
Duct installation
Request this service
Central AC installation
Request this service
Duct fabrication
Request this service
Cold room installation
Request this service
Electro-mechanical works
Request this service
Chiller & AHU installation
Request this service
HVAC design
Request this service
Copper piping works
Request this service
Air outlets and grilles installation
Request this service
Ventilation and exhaust systems
Request this service
HVAC controls and automation
Request this service
Duct insulation
Request this service
AC repair & faults
Request this service
AC cleaning
Request this service
Refrigerant charging
Request this service
Central AC maintenance
Request this service
Chiller maintenance
Request this service
AC removal & refitting
Request this service
Duct cleaning & sanitising
Request this service
AC servicing by brand
Request this service
Operation & maintenance contracts
Request this service
AHU maintenance
Request this service
Testing and commissioning
Request this service
Fridge & freezer service
Request this service
Cold rooms
Request this service
Display fridges & chillers
Request this service
Factory HVAC
Request this service
Warehouse HVAC
Request this service
Villa & home HVAC
Request this service
Hotel HVAC
Request this service
School HVAC
Request this service
Hospital HVAC
Request this service
Mosque HVAC
Request this service
Mall & retail HVAC
Request this service
Restaurant & cafe HVAC
Request this service
Government building HVAC
Request this service
Sports club HVAC
Request this service
Tower and office building HVAC
Request this service
University HVAC
Request this service
G90 galvanized steel and aluminium sheets
Request this service
Mueller and Lawton copper pipes
Request this service
Air grilles and diffusers (Saudi-made)
Request this service
Central AC accessories and materials
Request this service
Some of our work
Ductwork, rooftop units and diffusers, from work we've completed.
Customer reviews
What our customers say
- Waleed Daadouch
“The nicest treatment from the showroom team, and their prices are very competitive.”
Translated from Arabic
- Muhammadramzan 2641
“MashaaAllah. Services are so good. Behaviour and kindness 100/100. Prices are less then Market. Fully recommended”
- RHAM rhamLocal Guide
“May God grant them success. Refined and respectful treatment.”
Translated from Arabic
- shahzeb armani
“Wow. Prices are so comfortable. Outstanding services. People are so talented and nice”
- Shakeel Ahmed
“Nice experience very cooperative. Nice conducting with all customers”
- Tawfik AlyawerLocal Guide
“U can find all u need for air conditioning”
Your satisfaction matters to us! If you had a great experience with us, we'd love a 5-star rating and a kind review.
Worked with us? Leave a reviewService areas
We come to you anywhere in Jeddah
From Al Shiraa and Al Yaqout in the north to Al Thaghr and Al Quraiyat in the south, with our base in Al Aziziyah.

What sets this district apart
Al Kandarah is a mixed central area with residential towers, office buildings and mid-rise blocks, many built years ago and needing AC upgrades. Mixed-use towers here combine residential units with commercial offices in the same building, requiring a system allowing separate control and different airflows by use type. Ducts must handle shared use and variable pressure, with each residential or office unit needing its own thermostat and damper. High humidity and nearby coastal salt require strong insulation to maintain duct efficiency.
Al Kandarah is in central Jeddah, a mixed area of residential and office towers and old and new mid-rise buildings.
Most mixed-use towers in Al Kandarah use central HVAC with separate branch ducts for residential and office zones and individual thermostats per unit.
The AC setup in Al Kandarah
- 1
Separate branches for residential and office zones
From the same plant floor and evaporator, separate main branches go to residential floors and others to office zones, with separate thermostats per zone.
- 2
Flexible ducts in suspended ceilings and tight chases
Flexible ducts connect main branches to outlets in suspended ceilings or tight chases between units, easing installation in old towers without reconstruction.
- 3
Main risers in the tower's vertical core
Main vertical risers run through the old tower's core or main walls, minimising the need for large new chases and preserving the original building structure.
Before the visit
Before our visit in Al Kandarah
- 1
Survey tower spaces and existing chases
Inspect available spaces above ceilings and existing chases between units, identifying where new ducts can run without major reconstruction.
- 2
Confirm plant floor location and old chillers
Locate the current plant floor, old chillers and compressors, determining whether they stay or go, and where new branches will originate.
- 3
Coordinate with building management on working hours and access
Agree with building management on installation and maintenance times to avoid disrupting residents and offices, and confirm equipment and duct transport is possible through entrances and lifts.
More districts for Tower and office building HVAC
Other services in Al Kandarah
FAQ
Questions about Tower and office building HVAC
How does each tenant control their own temperature independently?
Each floor or zone is fed from its own plenum box, a damper controls the volume of air entering, and the thermostat sets the required temperature. This layout lets each tenant adjust their space without affecting the floors above or below.
Do tenant fit-out works affect cooling on other floors?
When the system is designed with independent zones, redistributing outlets or moving dampers inside one floor stays isolated from the rest of the building. We review the revised layout and rebalance that zone before the tenant moves in.
How does Jeddah's humidity affect duct design in towers?
High humidity means outdoor air carries a greater moisture load, which feeds into duct sizing and treated air volumes. Risers near the facade also need thorough glass-wool insulation to stop condensation forming on the duct surface inside the building.
Can you work while the building is occupied?
Yes, and that requires phasing the work floor by floor or wing by wing so cooling is never cut to neighbouring offices. We agree a programme with building management before starting and identify at the survey which sections can be isolated without disrupting daily operations.
How is cooling managed for the tower lobby and car park?
The lobby and car park have different requirements from office floors: ceiling heights differ, heat loads vary and ventilation needs change. The lobby needs diffusers suited to tall spaces, while the car park requires mechanical ventilation working alongside the cooling. The site survey determines the right design for each space.
How do you design AC for towers that mix residences and offices?
We divide the system into separate main branches for residential and office zones from the same evaporator, with individual thermostats and dampers per zone, letting residents control their units independent of offices.
Can new AC be installed in old towers without major reconstruction?
Yes, we run new ducts in suspended ceilings and existing chases and between walls without structural changes, using flexible ducts and short extensions to avoid demolition.
Does coastal humidity and salt affect duct durability?
Yes, humidity and salt accelerate rust in metal sheet and increase condensation in glass-wool insulation. We use moisture-resistant glass-wool and coat metal sheet with rust-proof protection, and install drain openings in long horizontal runs.
Old towers may lack easy access to duct runs, does that complicate installation?
Yes, we must survey available spaces and existing chases before design, and may need to open small gaps in ceilings or walls for new ducts. The tower's location and equipment access must be coordinated in advance with building management.