Ventilation and exhaust systems in Al Harrah, Jeddah

In Al Harrah, north-east Jeddah, ventilation and exhaust systems serve modern residential blocks, large housing compounds and commercial units. Alrabih's team designs duct from G90 galvanized sheet with dampers and balances the distribution of fresh and exhaust air in each space.

4.9 on Google
  • Effective exhaust
  • Balanced flow
  • Fresh air in

Clients We're Proud to Serve

Organisations and companies that trusted Alrabih with their projects.

  • Saudi Aramco
  • Ministry of Energy
  • Royal Saudi Land Forces
  • Royal Saudi Naval Forces
  • Al Baik
  • Centro Hotels by Rotana
  • King Abdullah Economic City
  • First Mills
  • Juffali
  • eXtra
  • Dr. Soliman Fakeeh Medical Center
  • Alesayi Motors
  • Abu Zaid
  • Water Desalination
  • Attieh Steel
  • SSCO
  • Creet
  • Emad Rizq
  • Alfaneyah
  • Rawat Alam Al Tasmeem
  • IBI Magix Arabia, Construction Services
  • Midtown for Construction
  • Petra Engineering Industries Co.
  • Hyrmas
  • Batterjee Medical College
  • Advanced Horizons Contracting Company
  • D.Metals
  • Benchbox, Masters of Space
  • Sadafco
  • Umm Al-Qura University
  • Saudi Arabian Drug Store (SADS)
  • Foamco
  • Ahmad A. R. Bin Afif Industries Co. (Sandwich Panel Factory)
  • Namariq
  • ALS

Is it for you?

When you need a dedicated ventilation system

  1. 1

    Smell or moisture that does not clear

    In a commercial kitchen, laundry or toilet block, steam and smells build up because stale air has nowhere to go. A properly designed exhaust system removes them at the source rather than just recirculating heavy air around the space.

  2. 2

    A plant room or workshop that overheats

    Electrical equipment and motors generate heat that shortens their life if it stays trapped. Mechanical ventilation draws hot air out from the top and brings cooler air in at a chosen point, keeping the operating temperature within a safe range.

  3. 3

    A car park or crowded prayer hall

    Exhaust fumes in enclosed car parks and carbon dioxide in large halls cannot be handled by cooling alone. The right system depends on the space and layout, and we plan the duct route and intake and exhaust points after a site survey.

Who it's for

  • Running a commercial kitchen with persistent steam and smells

    We survey the kitchen, design an exhaust system with galvanized duct and balancing dampers that remove steam and smells at the source, and bring fresh air in from a separate intake point.

    Ask on WhatsApp
  • Building a warehouse or workshop that needs mechanical ventilation

    We design the duct route and intake and exhaust positions during the construction phase, so the network is installed in the right place before ceilings and walls are finished.

    Ask on WhatsApp

What the job covers

What the installation covers

  • G90 galvanised sheet ducts
  • dampers for flow balancing
  • flexible connections at fans
  • separate intake and exhaust points
  • ducts insulated with glass wool
Request a quote

How we work

How we work

  1. 1

    Site survey and requirements

    We visit the site and note heat sources, smells, moisture and available duct routes, then fix intake and exhaust points so that expelled air cannot be drawn back into the building.

  2. 2

    System and route design

    We draw the duct route, damper and fan positions, and confirm that every space receives its share of air as the site demands.

  3. 3

    Duct fabrication and installation

    We fabricate the duct in our workshop from G90 galvanized sheet from SABIC to the site dimensions, then hang, insulate and connect it with flexible duct at the fans to reduce vibration.

  4. 4

    Balancing and handover

    After installation we adjust the dampers until flow is distributed at the right proportion through each outlet, then hand over the system with a one-year warranty.

Start with step one

Why Alrabih?

A designed system or just a hanging fan?

AlrabihThe usual way
Intake and exhaust pointsSeparate and positioned carefullyUncoordinated, exhaust re-enters
Flow distributionDampers balance every spaceSome spaces starved, others overloaded
DuctworkG90 galvanized sheet from SABICMixed or makeshift materials
Make-up airAccounted for in the designIgnored so fans lose pressure
Duct insulationGlass wool fitted carefullySkipped so moisture condenses
Request a quote

Everything your AC needs, from one team

From system design and duct fabrication to installation, commissioning and maintenance.

Some of our work

Ductwork, rooftop units and diffusers, from work we've completed.

  • Galvanized rectangular duct trunk with branch takeoffs and round diffusers, hung from a black ceiling, a Carrier unit visible behind — interior finishing stage.
  • Round diffusers and a spiral duct trunk in a tiled stairwell service shaft.
  • Rooftop ductwork and an exhaust fan, with Jeddah buildings in the background.
  • Rooftop packaged AC units with rectangular duct transitions, city buildings behind.
  • Insulated rooftop duct run beside a packaged unit, a warehouse roof in the background.
  • A grid of round diffusers in an open-plan office ceiling, mid-construction.
  • An insulated rooftop duct elbow, against a mountainous backdrop.
  • Large insulated ductwork running along a factory ceiling, with workers visible below.
  • A yellow round diffuser mid-installation, with spiral duct and a suspended ceiling grid.
  • Duct insulation wrap in progress on a construction site, bare duct still exposed.
  • A black-painted duct trunk with round diffusers and track lighting, in a finished retail interior.
  • An indoor AHU unit connected to round ductwork in a mechanical plant room, exposed concrete ceiling.
Browse all our work Similar project? Send us the details

Customer reviews

What our customers say

4.9

From 21 Google reviews

  • Waleed Daadouch

    “The nicest treatment from the showroom team, and their prices are very competitive.”

    Translated from Arabic

  • Muhammadramzan 2641

    “MashaaAllah. Services are so good. Behaviour and kindness 100/100. Prices are less then Market. Fully recommended”

  • RHAM rhamLocal Guide

    “May God grant them success. Refined and respectful treatment.”

    Translated from Arabic

  • shahzeb armani

    “Wow. Prices are so comfortable. Outstanding services. People are so talented and nice”

  • Shakeel Ahmed

    “Nice experience very cooperative. Nice conducting with all customers”

  • Tawfik AlyawerLocal Guide

    “U can find all u need for air conditioning”

Read every review on Google

Your satisfaction matters to us! If you had a great experience with us, we'd love a 5-star rating and a kind review.

Worked with us? Leave a review

Service areas

We come to you anywhere in Jeddah

From Al Shiraa and Al Yaqout in the north to Al Thaghr and Al Quraiyat in the south, with our base in Al Aziziyah.

Map of Jeddah by sector, with Alrabih's base in Al Aziziyah
Don't see your district?Message us. We most likely cover it.

What sets this district apart

Al Harrah is a relatively modern building area with multi-storey residential blocks and spacious housing compounds, where kitchens, bathrooms and commercial units need effective ventilation to remove humidity and odours. The modern foundations and large gaps between units allow air ducts to run more easily, but the system design must account for Jeddah's high coastal humidity and ensure the glass insulation keeps air distribution efficient.

Al Harrah sits in north-east Jeddah, a district of modern residential blocks and organized housing compounds with clear urban planning.

Most modern residential buildings here use central duct distributed from the basement or roof level, with standardized air outlets in bedrooms, living areas and kitchens.

The AC setup in Al Harrah

  1. 1

    Central duct from the basement level

    Most modern residential buildings have a basement or service level that allows the main duct to distribute easily to the residential units.

  2. 2

    Air outlets distributed in the main rooms

    Fresh air and exhaust outlets are placed uniformly in bedrooms, living areas and kitchens according to the flat's design.

  3. 3

    Flexible ducts connecting duct to outlets

    We use insulated flexible ducts to connect the main duct to the air outlets in each room.

Before the visit

Before our visit in Al Harrah

  1. 1

    Confirm duct routes in the design

    Check with the contractor and engineer where the main duct and branches will run before the visit, especially in the basement and on the roof.

  2. 2

    Provide adequate working space

    Make sure the installation team can access the basement, roof and spaces between units to fit the duct and outlets.

  3. 3

    Coordinate with other contractors

    Coordinate with electrical and plumbing contractors to avoid clashes and ensure all systems work together efficiently.

FAQ

Questions about Ventilation and exhaust systems

Does Jeddah's salty air affect ventilation ductwork?

Yes, Jeddah's humid, salt-laden air accelerates corrosion in low-grade sheet. We use G90 galvanized sheet from SABIC whose zinc coating resists the moisture and salinity. Outdoor intake points are positioned after the survey to avoid direct exposure to sea winds.

Can ventilation be added to an existing building without demolition?

In many cases yes. At the survey we check the space above false ceilings and possible routes through service areas. Some buildings allow a full run; others need alternative routes that we explain before work starts. The site decides.

What is the difference between natural and mechanical ventilation?

Natural ventilation relies on pressure differences, heat and facade openings, and it weakens on the hot, humid days that are common in Jeddah. Mechanical ventilation uses fans and duct that work regardless of weather, making it the right choice for kitchens, car parks and plant rooms.

Do you install ventilation systems in large and government projects?

Yes, we work on residential, commercial, industrial and government buildings across all districts of Jeddah. Project size affects pricing: we offer discounts by quantity and project size, and competitive prices across all works. Contact us with your project details and we will arrange a survey.

How do you make sure expelled air does not re-enter the building?

At the survey we note the prevailing wind direction and the positions of nearby openings, then separate the intake point from the exhaust point by a suitable distance and height. That separation is what prevents expelled air from circulating back into the space, and the conditions at each site decide the right arrangement.

What type of ventilation suits the modern residential buildings in Al Harrah?

Modern buildings need a central duct system with dampers to control the distribution of fresh and exhaust air in each unit. We design the system to fit the number of units and the size of each space.

In housing compounds, how do we route the exhaust from kitchens and bathrooms outside?

We route the exhaust through a separate duct to an outlet on the building roof or exterior wall, with dampers in each space to control the suction strength.

Does Jeddah's high humidity affect the duct and glass insulation?

Yes, coastal humidity requires strong glass insulation around the duct to prevent water condensation and protect metals from moisture. We select the right thickness based on local conditions.

Where do the thermostat wiring and electrical connections run in the system?

Wires typically run alongside the duct or in separate metal conduits, and we coordinate with the electrical contractor to ensure the routes and insulation are safe.

The Jeddah corniche in cool weather

Start with a site survey

Send us a description of the space you need ventilated on WhatsApp or call us, and we will book a survey visit Saturday to Thursday, 8 am to 8 pm.

CallWhatsApp