AC duct installation in Makkah, Makkah Region

AC duct installation in Makkah works within dense residential and hotel towers packed between rugged mountains. We are based in Jeddah: we fabricate the duct in our workshop, supply it to your Makkah site, install it and test the airflow before handover.

4.9 on Google
  • Sized branches
  • Sealed insulation
  • Clean return path

Clients We're Proud to Serve

Organisations and companies that trusted Alrabih with their projects.

  • Saudi Aramco
  • Ministry of Energy
  • Royal Saudi Land Forces
  • Royal Saudi Naval Forces
  • Al Baik
  • Centro Hotels by Rotana
  • King Abdullah Economic City
  • First Mills
  • Juffali
  • eXtra
  • Dr. Soliman Fakeeh Medical Center
  • Alesayi Motors
  • Abu Zaid
  • Water Desalination
  • Attieh Steel
  • SSCO
  • Creet
  • Emad Rizq
  • Alfaneyah
  • Rawat Alam Al Tasmeem
  • IBI Magix Arabia, Construction Services
  • Midtown for Construction
  • Petra Engineering Industries Co.
  • Hyrmas
  • Batterjee Medical College
  • Advanced Horizons Contracting Company
  • D.Metals
  • Benchbox, Masters of Space
  • Sadafco
  • Umm Al-Qura University
  • Saudi Arabian Drug Store (SADS)
  • Foamco
  • Ahmad A. R. Bin Afif Industries Co. (Sandwich Panel Factory)
  • Namariq
  • ALS

Is it for you?

When you need a properly designed duct fit

  1. 1

    One room cold, another warm

    The unit runs but one room is too warm while the next is too cold. The cause is usually unbalanced branches or a diffuser that was never adjusted, not a fault in the unit itself.

  2. 2

    Duct sweating and water on the ceiling

    Uninsulated cold duct sweats on the outside and water collects on the plasterwork above. Proper insulation with Armaflex or Kimmco stops the problem before it damages the ceiling finish.

  3. 3

    Installing a concealed unit in a new build

    The right time to fit duct properly is during the fit-out, before the false ceiling closes. We agree plenum dimensions, branch sizes and the return-air route at the survey before any work starts.

Who it's for

  • Fitting a concealed unit in your new villa

    Before the false ceilings close, we design the plenums, branches and return-air route to suit the unit and each room in the villa.

    Ask on WhatsApp
  • Sweating ceiling and uneven airflow in your building

    We inspect the existing branches and return-air path, re-insulate the cold duct, and set the dampers so temperature evens out across every section of the building.

    Ask on WhatsApp

What the job covers

What the duct installation covers

  • Supply and return plenums
  • Sized branch to each room
  • Armaflex or Kimmco insulation
  • Diffuser balancing with dampers
  • Airflow check before ceiling closes
Request a quote

How we work

How we work

  1. 1

    Site and unit survey

    We measure the rooms and study the unit's data and plenum spec, and we settle the return-air route before deciding on branch sizes.

  2. 2

    Design branches and plenum

    We size each branch so it takes the right share of air without starving rooms farther from the unit, and we plan a return path with a correctly sized intake opening.

  3. 3

    Fit and insulate

    We fix the plenums and branches using SMACNA-standard duct, then insulate every cold surface with a sealed layer suited to the building's conditions and its city's climate.

  4. 4

    Balance and hand over

    We set each diffuser damper and check airflow in every room with you before the false ceiling is closed, then leave the site clean.

Start with step one

Why Alrabih?

Designed duct or just connected duct?

AlrabihThe usual way
Branch sizingCalculated per roomConnected without sizing
Return airRouted with a sized intakeLeft to chance
Duct insulationSealed against sweatingThin or absent
Diffuser balanceDamper set per roomAll diffusers fully open
Pre-closure airflow checkDone with you before closingFaults found after ceiling closes
Request a quote

Everything your AC needs, from one team

From system design and duct fabrication to installation, commissioning and maintenance.

Some of our work

Ductwork, rooftop units and diffusers, from work we have completed.

  • Galvanized rectangular duct trunk with branch takeoffs and round diffusers, hung from a black ceiling, a Carrier unit visible behind — interior finishing stage.
  • Round diffusers and a spiral duct trunk in a tiled stairwell service shaft.
  • Rooftop packaged AC units with rectangular duct transitions, city buildings behind.
  • Insulated rooftop duct run beside a packaged unit, a warehouse roof in the background.
  • A grid of round diffusers in an open-plan office ceiling, mid-construction.
  • An insulated rooftop duct elbow, against a mountainous backdrop.
  • Large insulated ductwork running along a factory ceiling, with workers visible below.
  • A yellow round diffuser mid-installation, with spiral duct and a suspended ceiling grid.
  • Duct insulation wrap in progress on a construction site, bare duct still exposed.
  • A black-painted duct trunk with round diffusers and track lighting, in a finished retail interior.
  • An indoor AHU unit connected to round ductwork in a mechanical plant room, exposed concrete ceiling.
Browse all our work Similar project? Send us the details

Customer reviews

What our customers say

4.9

From 21 Google reviews

  • Waleed Daadouch

    “The nicest treatment from the showroom team, and their prices are very competitive.”

    Translated from Arabic

  • Muhammadramzan 2641

    “MashaaAllah. Services are so good. Behaviour and kindness 100/100. Prices are less then Market. Fully recommended”

  • RHAM rhamLocal Guide

    “May God grant them success. Refined and respectful treatment.”

    Translated from Arabic

  • shahzeb armani

    “Wow. Prices are so comfortable. Outstanding services. People are so talented and nice”

  • Shakeel Ahmed

    “Nice experience very cooperative. Nice conducting with all customers”

  • Tawfik AlyawerLocal Guide

    “U can find all u need for air conditioning”

Read every review on Google

Your satisfaction matters to us! If you had a great experience with us, we'd love a 5-star rating and a kind review.

Worked with us? Leave a review

Where we work

AC duct installation in cities near Makkah

We are based in Jeddah, and we supply duct and install across the Kingdom. All our services in Makkah

What sets this city apart

Makkah's residential and hotel towers are narrow and tall, so duct must take tight routes and short branches between floors. Shafts and narrow walls leave limited space for duct and copper, and the valley heat demands insulation and sealed joints. Hotels and buildings serving pilgrims need duct that handles high occupancy density and returns air quickly.

Makkah is a holy city in a valley surrounded by rugged granite mountains, built of residential towers, hotels and facilities serving pilgrims.

A common setup in Makkah hotels is concealed units with multi-floor ductwork and outdoor units on the roof.

All our services in Makkah

The AC setup in Makkah

  1. 1

    Short branches between tall floors

    In Makkah towers duct branches run between closely stacked floors, so they stay short and efficient to deliver cold air quickly.

  2. 2

    Rectangular sections in shafts

    Rectangular duct fits narrow shafts alongside electrical and plumbing runs in dense towers.

  3. 3

    Heavy insulation on hot roofs

    On hotel and tower roofs in Makkah, duct needs thick insulation against intense heat.

Before the visit

Before our visit in Makkah

  1. 1

    Provide plans for every floor

    Send architectural plans for every floor, because shaft locations and other services vary floor to floor.

  2. 2

    Mark outdoor and indoor unit positions

    Mark on the drawings where outdoor units go on the roof and indoor units (usually hidden in ceiling spaces), because these decide the duct and copper lengths.

  3. 3

    Arrange material access and storage

    Tell us how delivered duct can enter the site and where it will be stored before installation.

FAQ

Questions about AC duct installation

Why does duct sweat and cause dampness on the ceiling?

Warm air condenses the moment it meets a cold duct surface. A site survey establishes the precise requirements based on the building's conditions and its city's climate, then we insulate with a sufficient layer of Armaflex or Kimmco with all joints sealed, raising the outer surface temperature above the dew point and stopping the sweating.

Does a longer branch deliver less air to the room?

Yes, a longer branch resists airflow more than a short one. This is why we size each branch individually, so near and far rooms receive balanced quantities of air, and we complete the adjustment with dampers during start-up.

How do you size the return-air opening?

The intake opening must be large enough so the unit does not work against negative pressure that strains it. We check the unit data and plenum requirements and decide size and position at the survey, because placing it behind a closed door or away from occupied areas changes the calculation.

Does a large room need more than one air outlet?

Usually, yes. A long majlis or a wide living room cannot be served by one outlet, because the air cools one end and leaves the other. We spread the outlets along the room, split the branch between them, and keep them away from the return grille so cool air does not go straight back to the unit.

Does the duct material affect sweating and airflow balance?

Yes. Sheet metal duct holds its shape under air pressure, so flow quantities stay as designed. Flexible duct can compress or sag, changing its cross-section and upsetting the balance. We therefore fabricate the main branches from galvanised sheet in our workshop and use flexible duct only for the shortest possible connection at each diffuser.

How does duct fit in the narrow shafts and spaces of Makkah towers?

We design the duct after surveying the site and reviewing drawings, using rectangular sections and short branches so it fits in narrow spaces between floors without obstructing passage.

You are in Jeddah, so can the duct reach hotel sites in Makkah on schedule?

We fabricate the duct to the approved design and deliver it to your Makkah site according to the schedule agreed in the quote.

Does the heat in Makkah's valley affect cooling systems and duct?

The intense valley heat makes duct insulation on roofs and unconditioned spaces essential, and careful branch design to minimise resistance and heat loss, so cold air reaches upper floors.

Does duct design differ between hotels and residential towers in Makkah?

Yes. Hotels serving large guest numbers need larger return capacity and faster airflow balancing, while residential towers focus on each unit's efficiency separately.

Get even airflow in every room

WhatsApp a photo of the floor plan or site and your unit details, and we will book a survey in your district, Saturday to Thursday.

CallWhatsApp