Duct installation in Madinah, Madinah Region

Duct installation in Madinah suits hotels and residential towers near the centre, villas and hospitals. We fabricate the duct in our Jeddah workshop, supply it to your site in Madinah and install it, ensuring cold air reaches every space before handover.

4.9 on Google
  • Sealed joints
  • Proper insulation
  • Balanced branches

Clients We're Proud to Serve

Organisations and companies that trusted Alrabih with their projects.

  • Saudi Aramco
  • Ministry of Energy
  • Royal Saudi Land Forces
  • Royal Saudi Naval Forces
  • Al Baik
  • Centro Hotels by Rotana
  • King Abdullah Economic City
  • First Mills
  • Juffali
  • eXtra
  • Dr. Soliman Fakeeh Medical Center
  • Alesayi Motors
  • Abu Zaid
  • Water Desalination
  • Attieh Steel
  • SSCO
  • Creet
  • Emad Rizq
  • Alfaneyah
  • Rawat Alam Al Tasmeem
  • IBI Magix Arabia, Construction Services
  • Midtown for Construction
  • Petra Engineering Industries Co.
  • Hyrmas
  • Batterjee Medical College
  • Advanced Horizons Contracting Company
  • D.Metals
  • Benchbox, Masters of Space
  • Sadafco
  • Umm Al-Qura University
  • Saudi Arabian Drug Store (SADS)
  • Foamco
  • Ahmad A. R. Bin Afif Industries Co. (Sandwich Panel Factory)
  • Namariq
  • ALS

Is it for you?

When you need a specialist duct installer

  1. 1

    Rooms that cool unevenly

    One room freezing, another barely cool, even though they share the same system. The cause is usually a wrong branch takeoff or an unbalanced diffuser. We inspect the existing route and fix the fault at its real source, not at the thermostat.

  2. 2

    Adding a room or a new wing

    You have added a room or extended office space and need to connect it to the existing duct network. We inspect the current network to confirm it can carry the extension, then connect the new branch in a way that does not reduce airflow to the other rooms.

  3. 3

    Air leaking above the false ceiling

    You can hear air above the suspended ceiling, or some diffusers have grown weak since a previous maintenance visit. Unsealed joints waste cold air in the ceiling void before it reaches the rooms. Sealing them with Foster sealants solves the problem at its source.

Who it's for

  • Fitting out a new office that needs duct runs

    We survey the ceiling voids before they are closed and route duct runs with correct hangers and branch takeoffs.

    Ask on WhatsApp
  • Some rooms barely cool and you suspect the duct

    We inspect the duct route and fix wrong branch takeoffs and open joints at their exact location.

    Ask on WhatsApp

What the job covers

What the work covers

  • Duct routed above false ceiling
  • Hangers and supports fitted
  • Branch takeoffs and diffusers connected
  • Joints sealed with Foster
  • Duct insulated with Armaflex
Request a quote

How we work

How we work

  1. 1

    Site survey

    We inspect the ceiling void, plan a route clear of electrical and plumbing conflicts, and measure the actual dimensions of every section of the network.

  2. 2

    Hang and route the duct

    We fix hangers at correct spacing to prevent sag, then mount duct sections, connect branch takeoffs, and fit diffusers and grilles in the positions agreed at the survey.

  3. 3

    Seal and insulate

    We seal every joint with Foster sealants to stop air leakage, then insulate the duct with Armaflex or Kimmco to prevent condensation, accounting for the building's conditions and its city's climate, and keep the air cold along its full run.

  4. 4

    Check and hand over

    We run the system and confirm that air comes from every diffuser, then address any diffuser that seems weak before the false ceiling is closed and the site is handed over.

Start with step one

Why Alrabih?

Planned routing or quick routing?

AlrabihThe usual way
JointsSealed with Foster sealantsTape that fails in heat
InsulationFull Armaflex or KimmcoPatchy or missing
HangersCorrect spacing, no sagToo few, duct sags
Branch takeoffsPositioned to balance airflowWherever space allows
Duct routePlanned at surveyDecided on site
Request a quote

Everything your AC needs, from one team

From system design and duct fabrication to installation, commissioning and maintenance.

Some of our work

Ductwork, rooftop units and diffusers, from work we have completed.

  • Galvanized rectangular duct trunk with branch takeoffs and round diffusers, hung from a black ceiling, a Carrier unit visible behind — interior finishing stage.
  • Round diffusers and a spiral duct trunk in a tiled stairwell service shaft.
  • Rooftop packaged AC units with rectangular duct transitions, city buildings behind.
  • Insulated rooftop duct run beside a packaged unit, a warehouse roof in the background.
  • A grid of round diffusers in an open-plan office ceiling, mid-construction.
  • An insulated rooftop duct elbow, against a mountainous backdrop.
  • Large insulated ductwork running along a factory ceiling, with workers visible below.
  • A yellow round diffuser mid-installation, with spiral duct and a suspended ceiling grid.
  • Duct insulation wrap in progress on a construction site, bare duct still exposed.
  • A black-painted duct trunk with round diffusers and track lighting, in a finished retail interior.
  • An indoor AHU unit connected to round ductwork in a mechanical plant room, exposed concrete ceiling.
Browse all our work Similar project? Send us the details

Customer reviews

What our customers say

4.9

From 21 Google reviews

  • Waleed Daadouch

    “The nicest treatment from the showroom team, and their prices are very competitive.”

    Translated from Arabic

  • Muhammadramzan 2641

    “MashaaAllah. Services are so good. Behaviour and kindness 100/100. Prices are less then Market. Fully recommended”

  • RHAM rhamLocal Guide

    “May God grant them success. Refined and respectful treatment.”

    Translated from Arabic

  • shahzeb armani

    “Wow. Prices are so comfortable. Outstanding services. People are so talented and nice”

  • Shakeel Ahmed

    “Nice experience very cooperative. Nice conducting with all customers”

  • Tawfik AlyawerLocal Guide

    “U can find all u need for air conditioning”

Read every review on Google

Your satisfaction matters to us! If you had a great experience with us, we'd love a 5-star rating and a kind review.

Worked with us? Leave a review

Where we work

Duct installation in cities near Madinah

We are based in Jeddah, and we supply duct and install across the Kingdom. All our services in Madinah

What sets this city apart

Projects in Madinah range from hotels and central residential towers to suburban villas, hospitals and government buildings. Hotels and towers need a main duct with large sections and branches on every floor, while villas call for a compact duct above the false ceilings. The summer is hot and winter mild, which affects unit choice and insulation.

Madinah is a holy city on a plateau with volcanic basalt fields and palm groves, hot and dry in summer, mild in winter.

A common setup in Madinah hotels is ducted units in suspended ceilings with vertical chases in columns and walls.

All our services in Madinah

The AC setup in Madinah

  1. 1

    Main duct with large sections

    In hotels and hospitals a large rectangular main duct runs through suspended ceilings with supply and return openings.

  2. 2

    Duct branches on every floor

    Secondary ducts branch from the main duct to each room or residential unit, with dampers to control airflow.

  3. 3

    Vertical chases in columns

    Vertical chases run inside concrete columns or exterior walls to save horizontal space and height.

Before the visit

Before our visit in Madinah

  1. 1

    Have project plans and engineering drawings ready

    Send the ceiling, column and outdoor unit plans before the visit, so we can calculate duct routes and chase sizes accurately.

  2. 2

    Confirm outdoor unit and fan locations

    Agree the outdoor unit and fan positions or the dedicated roofs with the project engineer, as they determine duct and copper lengths.

  3. 3

    Arrange duct delivery and available space

    Tell us the site entrance, unloading capability and available space to store supplied duct temporarily before installation.

FAQ

Questions about Duct installation

How do you know the existing network can carry an extension?

Before any extension the technician checks the main duct dimensions and existing branch takeoffs, and measures air velocity at the current diffusers. If velocity is already low or the main run is narrow, he explains what must be corrected first. The site survey determines whether the extension is feasible on the existing network or whether the supply section needs to be enlarged.

Why does moisture form on the duct above the false ceiling?

Warm air trapped above the false ceiling meets the cold duct surface and moisture condenses on the outside of the duct wall. The most common cause is torn insulation or open joints that let warm air reach the bare metal. Armaflex or Kimmco insulation is fitted around the full perimeter and every joint is sealed with Foster sealants so no path remains for outside air to reach the duct surface.

Can you re-hang sagging duct without replacing the whole network?

Usually yes. The technician first identifies the cause of the sag: a failed hanger, a loose anchor point in the ceiling structure, or deformation of the duct itself. If the duct is undamaged, hangers are repositioned and spaced to prevent the sag from recurring. If the duct is deformed or the insulation has failed, the technician explains what needs replacing before re-hanging proceeds.

When is a damper needed at a branch takeoff?

A damper is fitted at a branch takeoff when the cooling load differs between zones connected to the same main duct run, for example a room with a large window compared with an interior corridor. Without a damper the path of least resistance takes most of the air and the other rooms receive less. The site survey identifies which branch points require a damper and which can be balanced by adjusting the takeoff size alone.

Can duct runs be extended after the false ceiling is closed?

It is usually possible by opening access panels or cutting limited sections in the false ceiling to reach the void above. The technician maps the route before starting to keep the number of openings to a minimum. Once the duct run, insulation and sealing are complete, panels are refitted or the cut sections are restored. The complexity and number of openings depend on the false ceiling type and any obstructions present, which the site survey establishes.

What is the difference between duct installation in a hotel and in a villa in Madinah?

A hotel needs a main duct with larger sections and branches on every floor and multiple units, while a villa needs a compact duct above the ceiling with one or two units.

How does the duct made in Jeddah reach a site in Madinah?

We fabricate the duct to the approved design sizes in our workshop, then supply it directly to your site in Madinah, and agree the delivery and installation dates with you in the quote.

Do the hot summers and mild winters affect duct and insulation choice in Madinah?

Intense summer heat requires strong insulation for duct crossing unconditioned spaces, and mild winters allow slightly less insulation on some runs. We assess each route after the site visit.

When should duct installation begin in a hospital under construction?

After the structure and main runs are complete and before ceilings and partition walls are fitted, so we can install chases and units and test them to strict hygiene standards.

Book a duct routing survey

WhatsApp a brief description of the space and a photo of the false ceiling if you can, and we will book a survey in your district, Saturday to Thursday.

CallWhatsApp