Industrial cooling done right
Factory HVAC in Harat Al Sham
Factory HVAC in Harat Al Sham, old downtown Jeddah, serves very small production shops in tight, old buildings. We design simple solutions that protect tight work areas and resist the coastal damp of this historic district.
- Industrial ventilation
- SMACNA ducting
- Shift-planned maintenance
Clients We're Proud to Serve
Organisations and companies that trusted Alrabih with their projects.
When does a factory need a specialist system?
- 1
Machine heat exhausting the workers
Compressors, motors and furnaces push out steady heat that scattered split units cannot handle. We assess every heat source on site and design a system that removes that heat and delivers cooled air precisely where people work.
- 2
A high roof that traps hot air
Hot air rises and collects under the roof while workers suffer at floor level. Evaporator positions, airflow angles and unit sizing all depend on the ceiling height and building shape, and the site survey decides each of these.
- 3
Production dust destroying equipment
In wood, metal and plastic factories, coarse dust enters units and damages compressors and coils. We select equipment suited to industrial environments and design air paths that separate cooling air from contaminated process air wherever possible.
Who it's for
Building a new factory that needs HVAC
We join at design stage to fix unit positions, duct routes and extraction before the roof is cast and machines are installed, so the system is built into the structure from the start.
Ask on WhatsAppExisting factory where heat is hurting output
We visit during live production, measure heat at its sources, and design additions or replacements that fix the problem without a long shutdown of your lines.
Ask on WhatsApp
What the system covers
- Survey of heat and process
- Cooling, ventilation and extraction design
- Round and rectangular duct fabrication
- Unit installation, connections, plenums
- Maintenance around shift patterns
How we work
How we work
- 1
Industrial site survey
Our team visits the factory during operation to measure actual heat from machines, map worker zones and critical processes, record ceiling heights and identify possible duct routes.
- 2
System design
We design central plant, distributed units or a combination to suit the factory, and fix the positions of extraction and ventilation units, duct sizes and damper locations before you approve the work.
- 3
Fabrication and installation
We fabricate duct in our own workshop from G90 galvanised or aluminium sheet to SMACNA standards, run Mueller copper in runs of up to 30 metres without welded joints, mount units and insulate pipework with Armaflex and Kimmco materials.
- 4
Commissioning and scheduled maintenance
We commission the system, check airflow distribution, refrigerant pressure and damper balance, then set up a preventive and corrective maintenance contract timed to fit around your production shifts.
Designed system or random units?
| Alrabih | The usual way | |
|---|---|---|
| Heat analysis | Measured during live operation | Visual guess only |
| Ducting | G90 sheet to SMACNA standards | Off-the-shelf, unsized duct |
| Extraction | Designed with the cooling | Standalone fans, uncoordinated |
| Maintenance | Scheduled around shifts | Only when it breaks |
| Copper runs | Mueller, no welds, 30 metres | Multiple welded joints |
Everything your AC needs, from one team
From system design and duct fabrication to installation, commissioning and maintenance.

Split AC installation
Request this service
Duct installation
Request this service
Central AC installation
Request this service
Duct fabrication
Request this service
Cold room installation
Request this service
Electro-mechanical works
Request this service
Chiller & AHU installation
Request this service
HVAC design
Request this service
AC repair & faults
Request this service
AC cleaning
Request this service
Refrigerant charging
Request this service
Central AC maintenance
Request this service
Chiller maintenance
Request this service
AC removal & refitting
Request this service
Duct cleaning & sanitising
Request this service
AC servicing by brand
Request this service
Operation & maintenance contracts
Request this service
AHU maintenance
Request this service
Fridge & freezer service
Request this service
Cold rooms
Request this service
Display fridges & chillers
Request this service
Factory HVAC
Request this service
Warehouse HVAC
Request this service
Villa & home HVAC
Request this service
Hotel HVAC
Request this service
School HVAC
Request this service
Hospital HVAC
Request this service
Mosque HVAC
Request this service
Mall & retail HVAC
Request this service
Restaurant & cafe HVAC
Request this service
Some of our work
Ductwork, rooftop units and diffusers, from work we've completed in Jeddah.
Customer reviews
What our customers say
- Muhammadramzan 2641
“MashaaAllah. Services are so good. Behaviour and kindness 100/100. Prices are less then Market. Fully recommended”
- shahzeb armani
“Wow. Prices are so comfortable. Outstanding services. People are so talented and nice”
- Tawfik AlyawerLocal Guide
“U can find all u need for air conditioning”
Your satisfaction matters to us! If you had a great experience with us, we'd love a 5-star rating and a kind review.
Worked with us? Leave a reviewService areas
We come to you anywhere in Jeddah
From Al Shiraa and Al Yaqout in the north to Al Thaghr and Al Quraiyat in the south, with our base in Al Aziziyah.

What sets this district apart
Harat Al Sham in old downtown Jeddah holds very small workshops, carpentry, blacksmithing, tailoring, repairs, in ancient buildings with medium ceilings and very tight spaces between walls. Heat from simple machines and shop furnaces is limited compared to factories, but the extremely tight space and high coastal humidity create a simultaneously damp and hot environment. Natural ventilation is very poor because buildings are closely packed, so we need small units and strong extraction to remove moisture and smoke.
Harat Al Sham in old downtown Jeddah, a historic district of tiny workshops in closely packed ancient buildings near the sea.
Most workshops here use only window units or a single split, no central systems due to tight spaces and relatively low ceilings.
The AC setup in Harat Al Sham
- 1
Small window units or light split
Tiny Al Sham workshops use small window units or just one split, as space allows nothing more.
- 2
Strong extraction fans to remove moisture
Coastal damp and wet walls need strong extraction fans, not just cool air, to expel humid air from the workshop.
- 3
Check and seal water seepage first
Before any ventilation system, we inspect walls and foundations to locate moisture sources and seal or insulate them.
Before the visit
Before our visit in Harat Al Sham
- 1
Clear a small space in front for equipment
Harat Al Sham's street is very tight and usually has parked cars, ensure space near the door so equipment can be carried in.
- 2
Inspect exterior walls and foundation for seepage
Before the visit, show us any wet walls or visible water seepage so we can inspect and recommend the best solution.
- 3
Tell us the building's age and past repairs
Old buildings may have longstanding structural issues, tell us about past repairs or known problems so we choose the right solution.
More districts for Factory HVAC
Other services in Harat Al Sham
FAQ
Questions about Factory HVAC
Can you cool just the worker zones without cooling the whole factory?
Yes, and we do it often. We design spot cooling for workstations or worker walkways using independent units or directed duct runs, rather than trying to cool the entire building volume. The right approach depends on the site and the process, and the survey decides it.
How do you handle heavy industrial dust in Jeddah?
We select units with a protection rating suited to the industrial environment and route airflow away from dust sources where the layout allows. In scheduled maintenance we inspect and clean coils, compressors and filters before deposits build up and affect unit performance.
Do you fabricate the large ducts a factory needs?
Yes, in our own workshop we fabricate round and rectangular duct to any size the design calls for, from G90 galvanised or aluminium sheet to SMACNA standards, including plenums, transitions and dampers needed to control air distribution.
Can you do maintenance between production shifts?
Yes, when we set up the preventive maintenance contract we agree times that fit your production schedule, whether between shifts or on rest days. The aim is that production lines are never stopped because of maintenance work.
What is the difference between process ventilation and worker-zone air conditioning?
Process ventilation targets heat and fumes produced by machinery and production lines, using exhaust fans and calculated fresh-air inlets sized to the heat load at each source. Worker-zone air conditioning aims to maintain a tolerable temperature at floor level without cooling the full volume of the building. A site survey of each factory decides which approach fits each area.
My workshop is very tight and very damp, how do you solve that?
We install a small window unit or light split, and add strong extraction ventilation to remove moisture and smoke from the tight space, and advise drying walls if there is water seepage.
The building is very old, can it take an outdoor unit on the wall?
We inspect the exterior wall first to confirm its strength, and may mount the unit at a strong point or use extra metal brackets to ensure safety.
Humidity causes mould in my workshop, will AC fix it?
AC reduces humidity, but the root issue is likely wall or foundation seepage. We fix ventilation and extraction, but recommend fixing the moisture source first.
The street is very narrow and has parked cars, how will your team get equipment in?
We agree on the nearest parking point and working hours, carry equipment by hand through narrow passages, and ask you to clear a small space in front if possible.












































































