HVAC design in Taif, Makkah Region

HVAC design in Taif differs from hot cities: mild summers thanks to altitude in the Sarawat Mountains, and cool winters that may need heating. The design calculates cooling and heating load together and selects the system and equipment before purchase or installation.

4.9 on Google
  • Accurate heat loads
  • System selection
  • Duct drawings

Clients We're Proud to Serve

Organisations and companies that trusted Alrabih with their projects.

  • Saudi Aramco
  • Ministry of Energy
  • Royal Saudi Land Forces
  • Royal Saudi Naval Forces
  • Al Baik
  • Centro Hotels by Rotana
  • King Abdullah Economic City
  • First Mills
  • Juffali
  • eXtra
  • Dr. Soliman Fakeeh Medical Center
  • Alesayi Motors
  • Abu Zaid
  • Water Desalination
  • Attieh Steel
  • SSCO
  • Creet
  • Emad Rizq
  • Alfaneyah
  • Rawat Alam Al Tasmeem
  • IBI Magix Arabia, Construction Services
  • Midtown for Construction
  • Petra Engineering Industries Co.
  • Hyrmas
  • Batterjee Medical College
  • Advanced Horizons Contracting Company
  • D.Metals
  • Benchbox, Masters of Space
  • Sadafco
  • Umm Al-Qura University
  • Saudi Arabian Drug Store (SADS)
  • Foamco
  • Ahmad A. R. Bin Afif Industries Co. (Sandwich Panel Factory)
  • Namariq
  • ALS

Is it for you?

Who needs a considered design?

  1. 1

    Owner planning a new build

    Before walls and ceilings are finished you still have the chance to route ducts and place units correctly. Early design prevents costly surprises during fit-out and delivers rooms that cool evenly from the first day of operation.

  2. 2

    Architect or contractor needing drawings

    The project needs mechanical drawings to co-ordinate with the structure, electrical and plumbing trades. We produce duct layout drawings, equipment positions and installation heights in a format the site can use directly.

  3. 3

    Existing building with uneven cooling

    Some rooms stay hot even with the AC running while others are over-cooled. The cause is usually wrong airflow distribution or uncalculated capacity. A redesign finds the fault and defines what needs changing before any new purchase.

Who it's for

  • Building a villa and want design before fit-out

    We calculate the heat load for every room in the villa and draw duct routes before ceilings are closed, so you avoid breaking the finished work later.

    Ask on WhatsApp
  • Running a commercial building with hot rooms

    We review the current airflow distribution and recalculate loads per space, then identify faults in the ducts or equipment and draw the required changes before any purchase.

    Ask on WhatsApp

What the job covers

What the design covers

  • Heat load per room
  • Right system type selected
  • Equipment from authorised brands
  • Duct distribution layout drawings
  • Equipment schedule for construction
Request a quote

How we work

How we work

  1. 1

    Gather building data

    We ask for the architectural drawings or visit the site to measure spaces and record glazing, orientation and internal loads from people, equipment and kitchens.

  2. 2

    Calculate heat loads

    We calculate the heat load for each space separately, accounting for the building's conditions and its city's climate alongside exposed facades, so every unit is sized on real load not guesswork.

  3. 3

    Select system and equipment

    Based on loads and building type we choose between splits, ducted systems, central air and chiller, and specify equipment from Carrier, YORK, General, Midea, Gree and Smart Gold to suit the project.

  4. 4

    Draw and deliver

    We draw duct routes, unit positions, diffuser locations and installation heights, and deliver a complete equipment schedule ready for construction or tendering.

Start with step one

Why Alrabih?

Calculated design or buying blind?

AlrabihThe usual way
Unit sizeBased on actual loadGuessed or oversized
Airflow distributionDrawing that achieves even flowDiffusers placed at random
Co-ordinationDrawings before fit-outCostly changes later
System typeSuited to building and budgetWhatever the shop suggests
Local climate and site conditionsAccounted for in equipment choiceDiscovered after installation
Request a quote

Everything your AC needs, from one team

From system design and duct fabrication to installation, commissioning and maintenance.

Some of our work

Ductwork, rooftop units and diffusers, from work we have completed.

  • Galvanized rectangular duct trunk with branch takeoffs and round diffusers, hung from a black ceiling, a Carrier unit visible behind — interior finishing stage.
  • Round diffusers and a spiral duct trunk in a tiled stairwell service shaft.
  • Rooftop packaged AC units with rectangular duct transitions, city buildings behind.
  • Insulated rooftop duct run beside a packaged unit, a warehouse roof in the background.
  • A grid of round diffusers in an open-plan office ceiling, mid-construction.
  • An insulated rooftop duct elbow, against a mountainous backdrop.
  • Large insulated ductwork running along a factory ceiling, with workers visible below.
  • A yellow round diffuser mid-installation, with spiral duct and a suspended ceiling grid.
  • Duct insulation wrap in progress on a construction site, bare duct still exposed.
  • A black-painted duct trunk with round diffusers and track lighting, in a finished retail interior.
  • An indoor AHU unit connected to round ductwork in a mechanical plant room, exposed concrete ceiling.
Browse all our work Similar project? Send us the details

Customer reviews

What our customers say

4.9

From 21 Google reviews

  • Waleed Daadouch

    “The nicest treatment from the showroom team, and their prices are very competitive.”

    Translated from Arabic

  • Muhammadramzan 2641

    “MashaaAllah. Services are so good. Behaviour and kindness 100/100. Prices are less then Market. Fully recommended”

  • RHAM rhamLocal Guide

    “May God grant them success. Refined and respectful treatment.”

    Translated from Arabic

  • shahzeb armani

    “Wow. Prices are so comfortable. Outstanding services. People are so talented and nice”

  • Shakeel Ahmed

    “Nice experience very cooperative. Nice conducting with all customers”

  • Tawfik AlyawerLocal Guide

    “U can find all u need for air conditioning”

Read every review on Google

Your satisfaction matters to us! If you had a great experience with us, we'd love a 5-star rating and a kind review.

Worked with us? Leave a review

Where we work

HVAC design in cities near Taif

We are based in Jeddah, and we supply duct and install across the Kingdom. All our services in Taif

What sets this city apart

Taif is a high mountain city with villas, hotels and farms around the urban centre. Its buildings range from family homes to tourist hotels and government buildings. Summers are moderately warm due to altitude and need cooling for a few months. Winters are cool and may need heating or combined heating and cooling. Design accounts for this climate diversity and the mix of stone villas and hotels on hillsides.

Taif, a highland city in the Sarawat Mountains in the Makkah Region, is known for rose farms and as a summer resort, with mild summers and cool winters.

Common designs in Taif are combined heating and cooling systems in villas and hotels to meet the different seasons.

All our services in Taif

The AC setup in Taif

  1. 1

    Combined heating and cooling systems

    Taif villas and hotels commonly use a single system providing cooling in summer and heating in winter, saving construction and maintenance costs.

  2. 2

    Unit placement on hillsides and high points

    Taif villas and hotels on hillsides place outdoor units on the roof or foundation depending on site topography, which may increase copper and duct length.

  3. 3

    Hotels and resorts with multi-zone control

    Taif's resort hotels need separate control for different zones, able to switch between cooling and heating by season or occupancy.

Before the visit

Before our visit in Taif

  1. 1

    Gather local climate data and drawings

    Send architectural plans and local temperature and humidity data for your site so we calculate heating and cooling load based on actual conditions.

  2. 2

    Specify heating and cooling needs

    Tell us which months need cooling and which need heating, plus expected operating hours, so we choose between combined and separate systems.

  3. 3

    Review site and terrain topography

    If the site is on a hillside or elevation, send a topographic map and photos so we decide the best locations for units, duct and copper runs.

FAQ

Questions about HVAC design

When is a chiller more suitable than split units?

The decision depends on the building area, number of spaces and how it is used. In large commercial and hotel buildings a chiller gives flexible control and simplifies central maintenance. In apartments and smaller villas a split or ducted system usually fits better. The calculated heat load is what determines the right choice for your building.

How does a large glazed facade affect the design?

Large glazing raises the heat load noticeably, especially on west and north-west facades. We calculate solar gain through each facade separately in line with the building's conditions and its city's climate, and this can change the unit type selected for that room or require extra diffusers to handle the higher load.

Can you design for an existing building with no architectural drawings?

Yes. When no drawings exist we visit the site and measure every space ourselves, recording facades, glazing and how each room is used. The survey takes longer than reviewing ready drawings, but the calculations still rest on real measurements rather than estimates, which is what makes the results reliable.

Does the design include diffuser types and dampers?

The drawings specify diffuser types, positions and sizes to match ceiling height and room shape, and show where dampers are needed to balance airflow to each zone. These details matter because a diffuser in the wrong place wastes a large part of the system capacity even when the units are correctly sized.

Does duct design differ between the ground floor and upper floors?

Yes. The top floor typically carries a higher heat load because the roof is directly exposed to the sun, which affects duct sizes and the number of diffusers needed on that level. We design each floor separately based on its own calculated load and show where dampers are needed to balance airflow between floors.

Why do design needs differ between Taif and hotter cities?

Taif sits above twelve hundred metres, so summer heat is lower and winter is cold. Design may need cooling only for some months but might also need heating. We balance cooling and heating needs across the year.

Do we need a separate heating system or one combined unit in Taif?

It depends on building type and budget. Some villas and hotels choose a combined system providing cooling and heating from one unit or system. Others prefer separate heating. We review the options and recommend the best fit for your needs and budget.

How do we calculate heat load in a mild mountain city?

We study actual summer and winter temperatures and humidity in Taif, sun exposure on facades and altitude. We also study expected operating hours in summer and winter. The result is a balanced design responding to actual needs without oversizing.

Do stone villas in Taif's mountains need special design?

Yes. Stone villas on hillsides may need good insulation in walls and roofs to prevent heat loss in winter and moisture penetration. We study construction methods and materials before calculating heat load and choosing equipment.

Start with the right design

WhatsApp your building drawings or site photos, or call us to arrange a survey, Saturday to Thursday from eight in the morning to eight in the evening.

CallWhatsApp