Ventilation and exhaust systems in Al Masarrah, Jeddah
In Al Masarrah, south Jeddah, administrative buildings, offices and residential flats need enhanced natural ventilation. Alrabih designs and installs ventilation systems using insulated ducts and balanced outlets to ensure fresh air reaches every space.
4.9 on Google- Effective exhaust
- Balanced flow
- Fresh air in
Clients We're Proud to Serve
Organisations and companies that trusted Alrabih with their projects.
Is it for you?
When you need a dedicated ventilation system
- 1
Smell or moisture that does not clear
In a commercial kitchen, laundry or toilet block, steam and smells build up because stale air has nowhere to go. A properly designed exhaust system removes them at the source rather than just recirculating heavy air around the space.
- 2
A plant room or workshop that overheats
Electrical equipment and motors generate heat that shortens their life if it stays trapped. Mechanical ventilation draws hot air out from the top and brings cooler air in at a chosen point, keeping the operating temperature within a safe range.
- 3
A car park or crowded prayer hall
Exhaust fumes in enclosed car parks and carbon dioxide in large halls cannot be handled by cooling alone. The right system depends on the space and layout, and we plan the duct route and intake and exhaust points after a site survey.
Who it's for
Running a commercial kitchen with persistent steam and smells
We survey the kitchen, design an exhaust system with galvanized duct and balancing dampers that remove steam and smells at the source, and bring fresh air in from a separate intake point.
Ask on WhatsAppBuilding a warehouse or workshop that needs mechanical ventilation
We design the duct route and intake and exhaust positions during the construction phase, so the network is installed in the right place before ceilings and walls are finished.
Ask on WhatsApp
What the job covers
What the installation covers
- G90 galvanised sheet ducts
- dampers for flow balancing
- flexible connections at fans
- separate intake and exhaust points
- ducts insulated with glass wool
How we work
How we work
- 1
Site survey and requirements
We visit the site and note heat sources, smells, moisture and available duct routes, then fix intake and exhaust points so that expelled air cannot be drawn back into the building.
- 2
System and route design
We draw the duct route, damper and fan positions, and confirm that every space receives its share of air as the site demands.
- 3
Duct fabrication and installation
We fabricate the duct in our workshop from G90 galvanized sheet from SABIC to the site dimensions, then hang, insulate and connect it with flexible duct at the fans to reduce vibration.
- 4
Balancing and handover
After installation we adjust the dampers until flow is distributed at the right proportion through each outlet, then hand over the system with a one-year warranty.
Why Alrabih?
A designed system or just a hanging fan?
| Alrabih | The usual way | |
|---|---|---|
| Intake and exhaust points | Separate and positioned carefully | Uncoordinated, exhaust re-enters |
| Flow distribution | Dampers balance every space | Some spaces starved, others overloaded |
| Ductwork | G90 galvanized sheet from SABIC | Mixed or makeshift materials |
| Make-up air | Accounted for in the design | Ignored so fans lose pressure |
| Duct insulation | Glass wool fitted carefully | Skipped so moisture condenses |
Everything your AC needs, from one team
From system design and duct fabrication to installation, commissioning and maintenance.

Split AC installation
Request this service
Duct installation
Request this service
Central AC installation
Request this service
Duct fabrication
Request this service
Cold room installation
Request this service
Electro-mechanical works
Request this service
Chiller & AHU installation
Request this service
HVAC design
Request this service
Copper piping works
Request this service
Air outlets and grilles installation
Request this service
Ventilation and exhaust systems
Request this service
HVAC controls and automation
Request this service
Duct insulation
Request this service
AC repair & faults
Request this service
AC cleaning
Request this service
Refrigerant charging
Request this service
Central AC maintenance
Request this service
Chiller maintenance
Request this service
AC removal & refitting
Request this service
Duct cleaning & sanitising
Request this service
AC servicing by brand
Request this service
Operation & maintenance contracts
Request this service
AHU maintenance
Request this service
Testing and commissioning
Request this service
Fridge & freezer service
Request this service
Cold rooms
Request this service
Display fridges & chillers
Request this service
Factory HVAC
Request this service
Warehouse HVAC
Request this service
Villa & home HVAC
Request this service
Hotel HVAC
Request this service
School HVAC
Request this service
Hospital HVAC
Request this service
Mosque HVAC
Request this service
Mall & retail HVAC
Request this service
Restaurant & cafe HVAC
Request this service
Government building HVAC
Request this service
Sports club HVAC
Request this service
Tower and office building HVAC
Request this service
University HVAC
Request this service
G90 galvanized steel and aluminium sheets
Request this service
Mueller and Lawton copper pipes
Request this service
Air grilles and diffusers (Saudi-made)
Request this service
Central AC accessories and materials
Request this service
Some of our work
Ductwork, rooftop units and diffusers, from work we've completed.
Customer reviews
What our customers say
- Waleed Daadouch
“The nicest treatment from the showroom team, and their prices are very competitive.”
Translated from Arabic
- Muhammadramzan 2641
“MashaaAllah. Services are so good. Behaviour and kindness 100/100. Prices are less then Market. Fully recommended”
- RHAM rhamLocal Guide
“May God grant them success. Refined and respectful treatment.”
Translated from Arabic
- shahzeb armani
“Wow. Prices are so comfortable. Outstanding services. People are so talented and nice”
- Shakeel Ahmed
“Nice experience very cooperative. Nice conducting with all customers”
- Tawfik AlyawerLocal Guide
“U can find all u need for air conditioning”
Your satisfaction matters to us! If you had a great experience with us, we'd love a 5-star rating and a kind review.
Worked with us? Leave a reviewService areas
We come to you anywhere in Jeddah
From Al Shiraa and Al Yaqout in the north to Al Thaghr and Al Quraiyat in the south, with our base in Al Aziziyah.

What sets this district apart
Al Masarrah is a mixed district with administrative buildings, residential towers and commercial offices, and wider streets than downtown. Most buildings here vary in age, from modern to relatively older, and some were not originally designed with separate ventilation systems. Installing ventilation in these buildings requires careful planning to run ducts through suspended ceilings and walls without interfering with existing electrical runs. Coastal humidity makes glass-wool insulation essential to prevent condensation and mould.
Al Masarrah sits in south Jeddah, a district of mixed administrative, residential and commercial buildings of varying ages.
Most residential towers and administrative buildings here use central air conditioning only and need a separate ventilation system to bring fresh air to individual flats or offices.
The AC setup in Al Masarrah
- 1
Ventilation for multi-storey residential towers
The residential tower needs an air plenum on the roof with insulated ducts serving several units per floor in a regular pattern.
- 2
Ventilation for independent commercial offices
Independent offices in the building may need a separate ventilation unit or shared branches from the main system, depending on agreement between the building owner and tenants.
- 3
Insulated flexible ducts to bypass suspended ceilings and runs
Older buildings needing ventilation may need insulated flexible ducts to navigate around existing ceilings and old runs.
Before the visit
Before our visit in Al Masarrah
- 1
Identify existing runs and expected obstacles
Before the visit, tell us where electrical, plumbing and suspended ceiling runs are to avoid conflicts when routing the duct.
- 2
Provide building plans and space map
Get a copy of the building plan showing space distribution and flats or offices to help design duct routes.
- 3
Agree installation schedule with management
In residential towers and office buildings, agree with building management on installation times that do not disturb residents or tenants.
More districts for Ventilation and exhaust systems
Other services in Al Masarrah
FAQ
Questions about Ventilation and exhaust systems
Does Jeddah's salty air affect ventilation ductwork?
Yes, Jeddah's humid, salt-laden air accelerates corrosion in low-grade sheet. We use G90 galvanized sheet from SABIC whose zinc coating resists the moisture and salinity. Outdoor intake points are positioned after the survey to avoid direct exposure to sea winds.
Can ventilation be added to an existing building without demolition?
In many cases yes. At the survey we check the space above false ceilings and possible routes through service areas. Some buildings allow a full run; others need alternative routes that we explain before work starts. The site decides.
What is the difference between natural and mechanical ventilation?
Natural ventilation relies on pressure differences, heat and facade openings, and it weakens on the hot, humid days that are common in Jeddah. Mechanical ventilation uses fans and duct that work regardless of weather, making it the right choice for kitchens, car parks and plant rooms.
Do you install ventilation systems in large and government projects?
Yes, we work on residential, commercial, industrial and government buildings across all districts of Jeddah. Project size affects pricing: we offer discounts by quantity and project size, and competitive prices across all works. Contact us with your project details and we will arrange a survey.
How do you make sure expelled air does not re-enter the building?
At the survey we note the prevailing wind direction and the positions of nearby openings, then separate the intake point from the exhaust point by a suitable distance and height. That separation is what prevents expelled air from circulating back into the space, and the conditions at each site decide the right arrangement.
Can ventilation be added to an older building without full redesign?
Yes, existing suspended ceilings can accommodate insulated ducts, minimizing impact on the original structure. We inspect the site first to find the best route and avoid conflicts with older runs.
Old electrical runs may block duct routing, how do you solve that?
We map existing runs before installation and choose a safe alternative route for the duct. In some cases, we may need insulated flexible ducts to navigate around obstacles.
Can suspended ceilings support insulated duct weight?
Standard suspended ceilings may not support heavy duct. We install a separate suspension system from the main roof structure to safely carry the duct and insulation weight. We verify ceiling strength during the site check.
Insulated duct takes up space, are there smaller options?
Duct size depends on the volume of fresh air needed. We design the system to be efficient and as compact as possible. The building's details and number of spaces determine the minimum required size, which we will discuss during the visit.