In Al Rabwah, central Jeddah, many residential flats rely on window AC units, and when they start leaking or making noise, they don't always need immediate replacement. Alrabih's team diagnoses the real issue accurately and repairs what is worth fixing.

  • Accurate diagnosis
  • Capacitor repair
  • Rust treatment

Clients We're Proud to Serve

Organisations and companies that trusted Alrabih with their projects.

  • Saudi Aramco
  • Ministry of Energy
  • Royal Saudi Land Forces
  • Royal Saudi Naval Forces
  • Al Baik
  • Centro Hotels by Rotana
  • King Abdullah Economic City
  • First Mills
  • Juffali
  • eXtra
  • Dr. Soliman Fakeeh Medical Center
  • Alesayi Motors
  • Abu Zaid
  • Water Desalination
  • Attieh Steel
  • SSCO
  • Creet
  • Emad Rizq
  • Alfaneyah
  • Rawat Alam Al Tasmeem
  • IBI Magix Arabia — Construction Services
  • Midtown for Construction
  • Petra Engineering Industries Co.
  • Hyrmas
  • Batterjee Medical College
  • Advanced Horizons Contracting Company
  • D.Metals
  • Benchbox — Masters of Space
  • Sadafco
  • Umm Al-Qura University
  • Saudi Arabian Drug Store (SADS)
  • Foamco
  • Ahmad A. R. Bin Afif Industries Co. (Sandwich Panel Factory)
  • Namariq
  • ALS

When your window unit needs attention

  1. 1

    Weak cooling even on full power

    The room stays warm even with the unit running at full. Most often the coil or filter is blocked with the dust and salt Jeddah's air carries; cleaning them brings the cooling back without any parts.

  2. 2

    Water leaking into the room

    Dripping inside the room does not always mean a mechanical fault. The unit needs a slight tilt toward the outside so condensate runs away. We check the tilt, the drain tray and the drain holes before anything else.

  3. 3

    Loud noise or a fan that will not spin

    Grinding or heavy vibration usually points to a fan with broken blades, a worn shaft or a foreign object inside the unit. A fan that does not start while the compressor hums is often a failed run capacitor.

Who it's for

  • Your flat's window unit drips onto the floor

    We check the unit tilt, drain tray and drain holes on site and correct the real cause so the dripping does not return.

    Ask on WhatsApp
  • Your shop's window unit runs but does not cool

    We diagnose the coil, filter, capacitor and thermostat at your shop and carry out the repair needed to restore cooling with the least disruption to your business.

    Ask on WhatsApp

What the repair covers

  • Filter and coil cleaned
  • Capacitor relay and thermostat tested
  • Fan blades and shaft checked
  • Tilt and drain tray corrected
  • Chassis rust report provided
Request a quote

How we work

How we work

  1. 1

    Describe the fault

    WhatsApp us what is happening: noise, drip or weak cooling. A photo of the front of the unit helps us know the model before the visit.

  2. 2

    On-site diagnosis

    The technician checks the filter, coil, fan, capacitor and thermostat in order, then tells you the real cause and what the repair needs before he starts.

  3. 3

    Repair or replace call

    If the repair is practical we complete it in the same visit. If the unit is old, the chassis is deeply rusted or the compressor fault is complex, we say so plainly and explain your options.

  4. 4

    Run test and handover

    After the repair we run the unit, check the cooling, confirm the drain flows and watch the current settle, then leave the room clean.

Real diagnosis or a quick guess?

AlrabihThe usual way
First stepSystematic check of each partReplace the easiest part
RustHonest chassis assessmentIgnored until it worsens
DrippingTilt and tray checked firstRefrigerant added without diagnosis
Replace decisionBased on actual conditionMay be rushed or delayed
Refrigerant typeRead from the unit nameplateWrong type may be added

Some of our work

Ductwork, rooftop units and diffusers, from work we've completed in Jeddah.

  • Galvanized rectangular duct trunk with branch takeoffs and round diffusers, hung from a black ceiling, a Carrier unit visible behind — interior finishing stage.
  • Round diffusers and a spiral duct trunk in a tiled stairwell service shaft.
  • Rooftop ductwork and an exhaust fan, with Jeddah buildings in the background.
  • Rooftop packaged AC units with rectangular duct transitions, city buildings behind.
  • Insulated rooftop duct run beside a packaged unit, a warehouse roof in the background.
  • A grid of round diffusers in an open-plan office ceiling, mid-construction.
  • An insulated rooftop duct elbow, against a mountainous backdrop.
  • Large insulated ductwork running along a factory ceiling, with workers visible below.
  • A yellow round diffuser mid-installation, with spiral duct and a suspended ceiling grid.
  • Duct insulation wrap in progress on a construction site, bare duct still exposed.
  • A black-painted duct trunk with round diffusers and track lighting, in a finished retail interior.
  • An indoor AHU unit connected to round ductwork in a mechanical plant room, exposed concrete ceiling.
Similar project? Send us the details

Customer reviews

What our customers say

4.8

From 10 Google reviews

  • Muhammadramzan 2641

    “MashaaAllah. Services are so good. Behaviour and kindness 100/100. Prices are less then Market. Fully recommended”

  • shahzeb armani

    “Wow. Prices are so comfortable. Outstanding services. People are so talented and nice”

  • Tawfik AlyawerLocal Guide

    “U can find all u need for air conditioning”

Read every review on Google

Your satisfaction matters to us! If you had a great experience with us, we'd love a 5-star rating and a kind review.

Worked with us? Leave a review

Service areas

We come to you anywhere in Jeddah

From Al Shiraa and Al Yaqout in the north to Al Thaghr and Al Quraiyat in the south, with our base in Al Aziziyah.

Map of Jeddah by sector, with Alrabih's base in Al Aziziyah
Don't see your district?Message us. We most likely cover it.

What sets this district apart

Al Rabwah is a medium-density residential district with multi-storey flats and some older villas, and many residents choose window units for their lower cost and easy installation. These units work hard through Jeddah's long summer and collect dust and coastal humidity quickly. Cleaning the coil, checking drainage and ensuring proper tilt can stop leaks and noise before repair costs spiral.

Al Rabwah sits in central Jeddah's urban heart, a mixed residential district blending apartment blocks with older homes.

Window AC units are very common in Al Rabwah flats, typically mounted directly in bedroom or living-room windows.

The AC setup in Al Rabwah

  1. 1

    One window unit per main room

    Most Al Rabwah flats have one unit mounted in a bedroom or living-room window, and some add a second unit in another room.

  2. 2

    Older window units still in operation

    Many Al Rabwah flats keep older window units for years and need regular maintenance to avoid leaks and noise.

  3. 3

    Drainage issues from humidity and dust

    Slow or blocked drainage is the most common issue in Al Rabwah window units because of coastal humidity and dust buildup.

Before the visit

Before our visit in Al Rabwah

  1. 1

    Clear the window of hanging items

    Make sure the window is clear of curtains and hanging items so the team can access the unit easily.

  2. 2

    Confirm a nearby power socket is available

    Check that there is a safe, adequately-rated power socket near the window if we need to rewire it.

  3. 3

    Locate any outdoor unit if one exists

    Some window units have a small external fan; make sure it (if present) is easy to access and clean if needed.

FAQ

Questions about Window AC repair

Can a window unit be repaired in the same visit?

Many faults, a clogged filter, a dirty coil, a failed run capacitor and a wrong tilt, are fixed in a single visit. If the unit needs a part the technician does not carry, we arrange a second visit once it is sourced.

How does Jeddah's salty air affect a window unit?

The damp salty air from the sea speeds up corrosion on the metal chassis, fan blades and coil fins. Units on sea-facing walls or higher floors corrode faster. We check how deep the rust goes and tell you honestly whether the unit is worth repairing or whether the chassis has reached the point where replacement saves more.

The unit runs but the compressor will not start. What causes that?

The most common cause is a failed run capacitor that can no longer give the compressor or fan the starting push it needs. The relay is the second likely cause. The technician tests both with instruments and confirms which is at fault before replacing anything.

Why does my window unit drip water into the room?

A window unit drains condensate out of the back, so if it tilts inwards or the drain holes in its base block, the water comes back into the room. We reset the tilt slightly outwards, clean the pan and drain holes, and check the frame is sealed so no water runs down the sides.

Can a faulty thermostat cause the compressor to cycle on and off rapidly?

Yes. A faulty thermostat can send wrong signals that make the compressor cut in and out abnormally, straining the circuit and reducing cooling. The technician tests the thermostat with instruments and separates it from other causes such as the relay or a supply voltage issue before any part is replaced.

My window unit drips water onto the floor, is it the coil or the drainage?

Usually the drain is blocked by dust and coastal dampness, or the unit was not tilted correctly outward. We check it, clear the drain and adjust the tilt, and in most cases the dripping stops.

My flat is small and the window frame is tight, can you fit a new unit without widening the opening?

It depends on the unit size and available space. We visit first to check the opening and frame, then advise what fits.

My unit clicks and rattles, is that the compressor or something we can fix?

It could be dust in the blower, a weak capacitor or loose mounting of the unit itself. We thoroughly inspect it and pinpoint the issue before advising whether repair or replacement makes sense.

High humidity in summer makes my unit run constantly, is that normal for Al Rabwah?

Jeddah is close to the sea and coastal humidity is very high in summer, so the unit works harder to cool damp air. Keeping the coil, filter and drain clean helps the unit run more efficiently.

The Jeddah corniche in cool weather

Get your window unit diagnosed today

WhatsApp a photo of the unit and a description of the fault, or call us, and a technician comes to your home, Saturday to Thursday.