Factory HVAC in Makkah, Makkah Region

Factory cooling in Makkah faces intense heat and humidity in the mountain valley, surrounded by dense hotel and residential towers. We design and install robust industrial systems that protect production and workers in a hot humid environment.

4.9 on Google
  • Industrial ventilation
  • SMACNA ducting
  • Shift-planned maintenance

Clients We're Proud to Serve

Organisations and companies that trusted Alrabih with their projects.

  • Saudi Aramco
  • Ministry of Energy
  • Royal Saudi Land Forces
  • Royal Saudi Naval Forces
  • Al Baik
  • Centro Hotels by Rotana
  • King Abdullah Economic City
  • First Mills
  • Juffali
  • eXtra
  • Dr. Soliman Fakeeh Medical Center
  • Alesayi Motors
  • Abu Zaid
  • Water Desalination
  • Attieh Steel
  • SSCO
  • Creet
  • Emad Rizq
  • Alfaneyah
  • Rawat Alam Al Tasmeem
  • IBI Magix Arabia, Construction Services
  • Midtown for Construction
  • Petra Engineering Industries Co.
  • Hyrmas
  • Batterjee Medical College
  • Advanced Horizons Contracting Company
  • D.Metals
  • Benchbox, Masters of Space
  • Sadafco
  • Umm Al-Qura University
  • Saudi Arabian Drug Store (SADS)
  • Foamco
  • Ahmad A. R. Bin Afif Industries Co. (Sandwich Panel Factory)
  • Namariq
  • ALS

Is it for you?

When does a factory need a specialist system?

  1. 1

    Machine heat exhausting the workers

    Compressors, motors and furnaces push out steady heat that scattered split units cannot handle. We assess every heat source on site and design a system that removes that heat and delivers cooled air precisely where people work.

  2. 2

    A high roof that traps hot air

    Hot air rises and collects under the roof while workers suffer at floor level. Evaporator positions, airflow angles and unit sizing all depend on the ceiling height and building shape, and the site survey decides each of these.

  3. 3

    Production dust destroying equipment

    In wood, metal and plastic factories, coarse dust enters units and damages compressors and coils. We select equipment suited to industrial environments and design air paths that separate cooling air from contaminated process air wherever possible.

Who it's for

  • Building a new factory that needs HVAC

    We join at design stage to fix unit positions, duct routes and extraction before the roof is cast and machines are installed, so the system is built into the structure from the start.

    Ask on WhatsApp
  • Existing factory where heat is hurting output

    We visit during live production, measure heat at its sources, and design additions or replacements that fix the problem without a long shutdown of your lines.

    Ask on WhatsApp

What the job covers

What the system covers

  • Survey of heat and process
  • Cooling, ventilation and extraction design
  • Round and rectangular duct fabrication
  • Unit installation, connections, plenums
  • Maintenance around shift patterns
Request a quote

How we work

How we work

  1. 1

    Industrial site survey

    Our team visits the factory during operation to measure actual heat from machines, map worker zones and critical processes, record ceiling heights and identify possible duct routes.

  2. 2

    System design

    We design central plant, distributed units or a combination to suit the factory, and fix the positions of extraction and ventilation units, duct sizes and damper locations before you approve the work.

  3. 3

    Fabrication and installation

    We fabricate duct in our own workshop from G90 galvanised or aluminium sheet to SMACNA standards, mount units and insulate pipework with Armaflex and Kimmco materials.

  4. 4

    Commissioning and scheduled maintenance

    We commission the system, check airflow distribution, refrigerant pressure and damper balance, then set up a preventive and corrective maintenance contract timed to fit around your production shifts.

Start with step one

Why Alrabih?

Designed system or random units?

AlrabihThe usual way
Heat analysisMeasured during live operationVisual guess only
DuctingG90 sheet to SMACNA standardsOff-the-shelf, unsized duct
ExtractionDesigned with the coolingStandalone fans, uncoordinated
MaintenanceScheduled around shiftsOnly when it breaks
Copper runsUp to 30 m, weld-freeMultiple welded joints
Request a quote

Everything your AC needs, from one team

From system design and duct fabrication to installation, commissioning and maintenance.

Some of our work

Ductwork, rooftop units and diffusers, from work we have completed.

  • Galvanized rectangular duct trunk with branch takeoffs and round diffusers, hung from a black ceiling, a Carrier unit visible behind — interior finishing stage.
  • Round diffusers and a spiral duct trunk in a tiled stairwell service shaft.
  • Rooftop packaged AC units with rectangular duct transitions, city buildings behind.
  • Insulated rooftop duct run beside a packaged unit, a warehouse roof in the background.
  • A grid of round diffusers in an open-plan office ceiling, mid-construction.
  • An insulated rooftop duct elbow, against a mountainous backdrop.
  • Large insulated ductwork running along a factory ceiling, with workers visible below.
  • A yellow round diffuser mid-installation, with spiral duct and a suspended ceiling grid.
  • Duct insulation wrap in progress on a construction site, bare duct still exposed.
  • A black-painted duct trunk with round diffusers and track lighting, in a finished retail interior.
  • An indoor AHU unit connected to round ductwork in a mechanical plant room, exposed concrete ceiling.
Browse all our work Similar project? Send us the details

Customer reviews

What our customers say

4.9

From 21 Google reviews

  • Waleed Daadouch

    “The nicest treatment from the showroom team, and their prices are very competitive.”

    Translated from Arabic

  • Muhammadramzan 2641

    “MashaaAllah. Services are so good. Behaviour and kindness 100/100. Prices are less then Market. Fully recommended”

  • RHAM rhamLocal Guide

    “May God grant them success. Refined and respectful treatment.”

    Translated from Arabic

  • shahzeb armani

    “Wow. Prices are so comfortable. Outstanding services. People are so talented and nice”

  • Shakeel Ahmed

    “Nice experience very cooperative. Nice conducting with all customers”

  • Tawfik AlyawerLocal Guide

    “U can find all u need for air conditioning”

Read every review on Google

Your satisfaction matters to us! If you had a great experience with us, we'd love a 5-star rating and a kind review.

Worked with us? Leave a review

Where we work

Factory HVAC in cities near Makkah

We are based in Jeddah, and we supply duct and install across the Kingdom. All our services in Makkah

What sets this city apart

Factories in Makkah sit within dense hotel, residential and commercial towers in a mountain valley with intense heat and high humidity, especially during pilgrimage season. Cooling loads are very high because external heat and humidity rise together. We choose units and ductwork after studying the surrounding environment and intensive operating schedules.

Makkah is a holy city in a valley among rugged granite mountains, hot and dry most of the year with humidity in the valleys, built densely with hotel, residential and service towers.

A factory in Makkah typically needs a very high-capacity cooling unit with a robust condenser on the roof and thickly insulated ductwork against external heat and humidity.

All our services in Makkah

The AC setup in Makkah

  1. 1

    Central unit in an isolated room

    The central unit sits in a separate room insulated against external heat and humidity, with a protected air intake, so the inlet air stays cool.

  2. 2

    Condenser on roof with sun protection

    The condenser is mounted on the factory roof with strong shading or ventilation space, because direct sun heat reduces condenser efficiency in hot humid conditions.

  3. 3

    Moisture-controlled insulated ducts

    Ducts are heavily insulated against heat loss and condensation, and outlets are precisely sealed to minimise moisture ingress from outside the system.

Before the visit

Before our visit in Makkah

  1. 1

    Provide site plans and process details

    Send plans, engineering drawings and process details before the visit so we understand the surrounding environment, heat load and site humidity.

  2. 2

    Confirm condenser placement on roof

    Agree with us on the condenser mounting location and available shading or ventilation, because this determines cooling efficiency and distance from the unit.

  3. 3

    Coordinate with factory management and site

    Tell us the intensive operating schedule and high-load seasons in your factory so we can time installation to avoid impact on production or quality.

FAQ

Questions about Factory HVAC

Can you cool just the worker zones without cooling the whole factory?

Yes, and we do it often. We design spot cooling for workstations or worker walkways using independent units or directed duct runs, rather than trying to cool the entire building volume. The right approach depends on the site and the process, and the survey decides it.

How do you handle heavy industrial dust in factories?

We select units with a protection rating suited to the industrial environment and route airflow away from dust sources where the layout allows. In scheduled maintenance we inspect and clean coils, compressors and filters before deposits build up and affect unit performance.

Do you fabricate the large ducts a factory needs?

Yes, in our own workshop we fabricate round and rectangular duct to any size the design calls for, from G90 galvanised or aluminium sheet to SMACNA standards, including plenums, transitions and dampers needed to control air distribution.

Can you do maintenance between production shifts?

Yes, when we set up the preventive maintenance contract we agree times that fit your production schedule, whether between shifts or on rest days. The aim is that production lines are never stopped because of maintenance work.

What is the difference between process ventilation and worker-zone air conditioning?

Process ventilation targets heat and fumes produced by machinery and production lines, using exhaust fans and calculated fresh-air inlets sized to the heat load at each source. Worker-zone air conditioning aims to maintain a tolerable temperature at floor level without cooling the full volume of the building. A site survey of each factory decides which approach fits each area.

Do Makkah's heat and humidity change the unit types you choose?

Yes. Intense heat and humidity together demand very high cooling capacity and strong dehumidification, plus additional cooling for the outdoor condenser and pipes against condensation. We select units and insulation after surveying the site and production processes.

How do you deliver duct and units from Jeddah to a factory in Makkah?

We fabricate duct in our workshop to the sizes designed for your factory's load, deliver it to the site with the units, condenser and copper tubing, and install the complete system. We agree delivery and installation dates with you in the quote.

Does high humidity in Makkah require more maintenance for the ductwork?

Yes. High humidity makes tight insulation and sealed joints essential to prevent condensation and corrosion. We use thick insulation and robust-jointed ductwork, and include regular inspections to ensure insulation and joint integrity.

When should cooling system installation start in a new factory in Makkah?

After the structure and roof are complete and the condenser is mounted, but before heavy equipment installation. This lets us install duct and units without conflicts, and we coordinate timing to avoid production delays.

Start with a factory survey

WhatsApp us the factory type, its approximate size and district, or call us, and we will arrange a site visit Saturday to Thursday.

CallWhatsApp